SJ 46A & SJ 46AJ
December 2007 Page 35
TM
Section 2 - Operation Function Tests
Test Function Enable Switch and All •
Boom Functions
WARNING
Ensure that there are no personnel or
obstructions in test area and there is
sufficient room for boom to swing.
1. Do not hold
function enable switch.
Attempt to activate each boom and
platform switch.
Result: All boom and platform functions
should not operate.
2. Hold
function enable switch
and activate each boom and platform
function.
Result: All boom and platform functions
should operate as selected.
Test Platform Self-leveling•
1. Lower boom to stowed position.
2. Adjust platform to a level position using
platform leveling switch.
3. Raise
and lower main
boom through a full cycle.
Result: Platform should remain level at all
time.
Test Emergency Power•
1. On base control console, push in
emergency stop button to turn
engine off.
2. On platform control console, push in
emergency stop button.
CAUTION
When operating on auxiliary power, do
not operate more than one function
at a time to avoid overloading 12-Volt
auxiliary pump motor. Do not use
emergency power unit continuously for
more than two minutes.
Emergency
Stop
Base Control Console
Start/Function Enable/
Emergency Power
Switch
Base/Off/Platform Key
Switch