Page 36 December 2007
SJ 46A & SJ 46AJ
Function Tests Section 2 - Operation
NOTE
To conserve battery power, test each
function through a partial cycle.
3. On base control console, pull out
emergency stop button.
4. O n b a s e c o n t r ol c on s o l e , t u r n
base/off/platform key switch to
platform position.
5. Select
emergency power position
from start/function enable/emergency
power switch and activate each boom
function.
Result: All selected functions should
operate.
6. Turn base/off/platform key switch to
base position.
7. Select
emergency power position
from start/function enable/emergency
power switch and activate each boom
function.
Result: All selected functions should
operate.
NOTE
The emergency power unit has two-minute
duty cycle.
Test Base/Off/Platform Switch•
1. Ensure both
emergency stop
buttons are pulled out.
2. Start engine.
3. On base control console, turn base/off/
platform key switch to “ ” off position.
Result: Engine should shut down and
aerial platform functions should not
operate.
4. On base control console, turn base/off/
platform key switch to
platform
position.
WARNING
Ensure that you maintain three points of
contact to mount/dismount platform.
5. Enter platform and close gate.
6. On platform control console, select
on position from engine enable switch.
Emergency
Stop
Base Control Console
Base/Off/Platform Key
Switch
Start/Function Enable/
Emergency Power
Switch