SkyTrac Systems Ltd.
Document Rev. 02.010 ISAT-100-OPD-SOI Page 5 of 26
Restricted Proprietary and Confidential Information
2.6 Environmental Test Summary
The following table summarizes DO-160D Environmental Testing for the SkyTrac
ISAT-100 Airborne Position/Data Communicator.
Section of
DO-160D
Condition
Category
Comments
4.5
4.6, 4.6.2
Temperature & Altitude
Rapid decompression
[A4, D1] Meets category requirements
5.0 Temperature Variation B Meets category requirements
6.0 Humidity A Meets category requirements
7.0 Operational Shock and
Crash Safety
B Meets category requirements
8.0 Vibration
1)
SMB/UF Meets fixed wing standard
vibration, helicopter robust vibration
9.0 Explosion Proofness X No test required. See Note 1.
10.0 Waterproofness X No test required
11.0 Fluid Susceptibility X No test required
12.0 Sand and Dust X No test required
13.0 Fungus Resistance X No test required
14.0 Salt Spray X No test required
15.0 Magnetic Effect Z <0.3m for 1 degree deflection
16.0 Power Input B Meets category requirements
17.0 Voltage Spike B Meets category requirements
18.0 AF Conducted
Susceptibility
X No test required
19.0 Induced Signal
Susceptibility
X No test required
20.0 RF Susceptibility X No test required
21.0 RF Emissions M Meets category requirements
22.0 Lightning Induced
Transient Susceptibility
X No test required. See Note 1.
23.0 Lightning Direct Effects X No test required
24.0 Icing X No test required
25.0 ESD X No test required
Note 1: Analysis provided to Transport Canada meets category requirements.