4) Start the engine
A. Recoil start—Turn the engine switch to the ON posion. Pull the
starter grip lightly unl resistance is felt, then pull briskly. DO NOT
allow the starter grip to snap back against the casing, return it
gently to prevent damage to starter.
B. Electric Key Start—Turn the engine switch to the start posion and
hold unl engine starts (no more than 5 seconds) and return switch
to the ON posion. If the engine fails to start wait 10 seconds
before retrying.
5) Posion the throle lever to normal operang posion and begin
vacuuming
6) Vacuuming with higher rpm is permissible but should not be
undertaken for prolong periods of me
NOISE EMISSION Sound Power Level (LWA) 107 dB
91 dB(A) @ 1M at Normal Operang Level 3,0003,300 rpm
96 dB(A) @ 1M at Maximum set 3,850 rpm
Ear Protecon MUST be worn at ALL mes when equipment is in use
HANDLING
The vacuum cleaner weight is 78Kg (Key Start 87Kg) empty and will be
considerably heavier when the collecon drum is full, be parcularly careful when
manoeuvring and liing for which a Risk Assessment should be undertaken and