7 Mounting the Power Unit
SMA Solar Technology AG
Replacement ManualSBxx-1SP-US-41-PU-RM-xx-1014
7 Mounting the Power Unit
1. Ensure that the DC load-break switch is switched off (see Section5, page10).
2. Plug the new Power Unit into the Connection Unit. Ensure that the screw holes on the left and
right sides of the PowerUnit are directly over those of the ConnectionUnit; and the cables
protruding from the PowerUnit must not be pinched.
3. Tighten two screws with two washers on the right and left side of the PowerUnit (TX25)
(torque: 6Nm ± 0.3Nm (53in-lb ± 2.65in-lb)).
4. If the enclosure lid of the new Power Unit is a transport lid (see information on the enclosure
lid), replace the transport lid of the new Power Unit with the enclosure of the defective Power
Unit:
• Unscrew all screws of the upper enclosure lid
(TX25) and remove it.
• Position the upper enclosure lid with the six
screws and serrated conical spring washers on
the enclosure and tighten it in the specified
order (TX25, torque: 6Nm (53in)).
5. Pull the ribbon cable used to connect the
communication assembly to the PowerUnit into the
ConnectionUnit, and plug it into the jack on the
communication assembly.
COM
SPS
AC-out
D-IN
SPS
A B
M1
X1 X2
M2
ANT.
FCC ID: SVF-KP20
IC: 9440A-KP20
ENGLISH