6 Mounting
SMA Solar Technology AG
Operating manualSTP110-60-BE-en-1628
Procedure:
1. Screw the bracket parts to the ends of the
connecting rod (PH2, torque: 1.5Nm) using the
cheese head screws (M4x10) to mount the
mounting bracket.
1
2x2x2x
2
2. Align the mounting bracket using a spirit level and mark the drilling positions on the profile
rails.
3. Drill the bore holes (Ø 12 mm) at the marked areas.
4. Attach the mounting bracket to the profile rails
(AF16, tightening torque: 35Nm) using 4 hex
screws (M10x45). In this process, use 1 washer, 1
spring washer and 1 hex nut each.
1
4x4x4x
2
5. Remove the sealing screws on the sides of the
inverter using a flat-blade screwdriver (4mm).
4x4x4x