13 Technical Data
SMA Solar Technology AG
Operating manual STP8-10-3AV-40-BE-en-12 97
13 Technical Data
13.1 DC/AC
13.1.1 SunnyTripower 8.0 / 10.0
STP8.0-3AV-40 STP10.0-3AV-40
Maximum PV array power 15000Wp 15000Wp
Maximum input voltage 1000V 1000V
MPP voltage range 260V to 800V 320V to 800V
Rated input voltage 580V 580V
Minimum input voltage 125V 125V
Initial input voltage 150V 150V
Maximum input current, input A 20A 20A
Maximum input current, input B 12A 12A
Maximum short-circuit current,
inputA*
30 A 30 A
Maximum short-circuit current,
input B*
18 A 18 A
Maximum reverse current into
the PV array
0A 0A
Number of independent MPP
inputs
2 2
Strings, input A 2 2
Strings, input B 1 1
Surge category in accordance
with IEC60664-1
II II
* In accordance with IEC62109-2: ISC PV
AC Output
STP8.0-3AV-40 STP10.0-3AV-40
Rated power at 230V, 50Hz 8000W 10000W
Maximum apparent AC power
at cosφ=1
8000VA 10000VA
Rated grid voltage 230V 230V