Do you have a question about the SMA Sunny Tripower CORE2 and is the answer not in the manual?
Max. DC voltage | 1100 V |
---|---|
Max. input voltage | 1100 V |
Number of MPP trackers | 12 |
Number of independent MPP inputs | 24 |
THD | < 3% |
AC grid frequency | 50 Hz / 60 Hz |
Adjustable AC frequency range | 45 Hz - 65 Hz |
Max. input current per MPP tracker | 26 A |
Operating temperature range | -25°C to +60°C |
Degree of protection | IP66 |
Maximum Efficiency | 98.6% |
Max. apparent AC power | 110000 VA |
AC nominal voltage | 400 V |
DC nominal power | 110000 W |
Cooling | Active |
Describes the product's intended use in industrial environments and compliance.
Provides crucial safety information to be observed at all times when working.
Describes the product's interfaces and communication capabilities.
Outlines necessary conditions and warnings for selecting a suitable mounting location.
Details the allowed and disallowed orientations for mounting the product.
Specifies required distances to walls and other objects for proper installation.
Provides instructions and requirements for mounting the product using profile rails.
Step-by-step guide for securely mounting the product onto a wall.
Details permitted grid configurations and essential electrical connection requirements.
Lists specifications and material requirements for AC cables used with the inverter.
Specifies requirements for DC cables, including diameter, cross-section, and voltage rating.
Step-by-step procedure for connecting the AC cable, including safety precautions.
Instructions for performing additional grounding of the inverter for safety.
Procedure for connecting network cables, including safety warnings about overvoltage.
Overview and assembly instructions for DC connectors.
Procedure for connecting the PV array, including safety warnings and notices.
Detailed procedure for connecting a fast stop switch to digital inputs.
Steps for commissioning an inverter without a System Manager.
Steps for commissioning an inverter within a system managed by a System Manager.
Final steps for commissioning the inverter, including checks and switch-on procedures.
Guides on connecting to the inverter's user interface via local network.
Instructions for establishing a direct Ethernet connection to the inverter.
Procedure for logging into the user interface with installer credentials.
Procedure for logging into the user interface with service provider credentials.
Guide to changing user passwords for enhanced system security.
Procedure for adjusting operating parameters to optimize inverter performance.
Essential steps to set the correct country data set for grid compliance.
Procedure to activate the fast stop function via the inverter's user interface.
Instructions for updating the inverter's firmware using an update file.
Details "Grid overvoltage" event, explanation, and corrective measures.
Details "Temporary grid overvoltage" event, explanation, and corrective measures.
Details "Grid undervoltage" event, explanation, and corrective measures.
Details "Low voltage" event, explanation, and corrective measures.
Details "Temporary AC overcurrent" event, explanation, and corrective measures.
Details "Grid overfrequency" event, explanation, and corrective measures.
Details "Grid underfrequency" event, explanation, and corrective measures.
Details "Grid power failure" event, explanation, and corrective measures.
Details "Supply grid fault" event, explanation, and corrective measures.
Details "10-minute grid overvoltage" event, explanation, and corrective measures.
Details "Grid overvoltage" event, explanation, and corrective measures.
Details "Unbalanced load of grid voltage" event, explanation, and corrective measures.
Step-by-step guide to safely disconnect all product connections.
Instructions for safely disassembling the product for removal or transport.
Critical safety precautions to be observed during maintenance activities.