EasyManua.ls Logo

SmartPool NC71AU - Page 38

SmartPool NC71AU
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
w w w . s m a r t p o o l . c o m
38
4) Perform a Self Test: Place the unit upside
down on the bench, plug in the Power
Supply and the Cable. Turn Power Supply
to the ON position: the Pump Motor
should run and then the Drive Motor
should turn on. Shut the unit down after
the Drive Motor starts to run.
If the cleaner is “Dead In Water” then there should not be any movement from the unit.
If the cleaner has “No Suction” then the Pump Motor should not turn on.
If the cleaner “Does Not Move” then the Drive Motor will not turn on or the unit will shut
down when the Drive Motor goes to turn on.
If the cleaner “Stands On End/Wheelies” or “Back and Forth” then the unit is most likely
going to perform a Self Test. If the Filter Bag was improperly installed, then water test the unit
without a Bottom Lid or Filter Bag.
RESULTS