Doc. no. AMX-OMU0058-C
-13-
3-3.AMD Series
Note 1) When selecting Option H, Option J
Note 2) Air flow capacity with 20
o
C, atmospheric pressure and relative humidity of 65 %.
Note 3) Air flow capacity with 32
o
C, and when calculated to atmospheric pressure.
Note 4) Filtration efficiency for conditions below in addition to the rated conditions above [Test condition
ISO8573-4: 2010 compliant].
* Flow capacity, inlet pressure and the amount of solid bodies at the filter inlet are stable.
* New element
Note 5) Oil mist density at outlet for conditions below in addition to the rated conditions above.
【Compliant to test condition ISO8573-2:2010 and test method ISO12500-1:2007】
* Oil mist concentration on the filter inlet side = 30mg/m3(ANR)
* Flow capacity, inlet pressure and the Oil mist concentration at the filter inlet are stable.
* New element
Model
AMD70D AMD80D AMD90D
Port size
1、1 1/2
1 1/2
1 1/2、2
Weight 3.4kg 4.7kg 5.0kg
Scope
Fluid Compressed air
Inlet air pressure range 0.1 to 1.0MPa (1.6MPa)
Note1)
Operating fluid
temperature
-5 to 60
O
C (No freezing)
Ambient temperature -5 to 60
O
C (No freezing)
Proof pressure 1.5MPa (2.4MPa)
Note1)
Rated conditions
Air flow capacity
m
3
/min(ANR)
Note2)
7.0 11.0 14.5
Flow capacity of
the compressor intake
condition
m
3
/min
Note3)
7.3 11.5 15.1
Inlet air pressure 0.7MPa
Filtration
Note 4)
0.01µm (Filtration efficiency: 99.9%)
Oil mist density at outlet
Note 5)
Max 0.1mg/m3 (ANR)(≒0.08ppm)
(Before saturated with oil,less than 0.01 mg/m3(ANR)≒0.008ppm)