Piping
- Before piping is connected, it should be thoroughly flushed with air or washed to
remove chips, cutting oil and other debris from inside the pipe.
- When screwing piping or fittings into ports, ensure that chips from the pipe threads
or sealing material do not enter the piping.
- Furthermore, when pipe tape is used, leave 1.5 to 2 thread ridges exposed at the end
of the threads.
- Reverse connection is not available. IN and OUT should be connected correctly.
The compressed air inlet is indicated with a flow direction symbol on the top of the product.
-Drain piping of the auto drain should be performed with an appropriate tube diameter
and length.
Tube I.D. φ6.5 (φ1/4 inch) or more, length within 5m (200 inch)
- Riser pipework of the auto drain should be avoided.
It may cause the operation failure of the auto drain.
- Be sure to connect piping for drain when the drain guide is mounted.
As a valve function is not equipped, drainage or compressed air will be exhausted if piping
is not connected.
Also, the piping should be performed with the drain guide held by a spanner.
Otherwise, the bowl might be broken.