SMCGB10-Z Glass Break Sensor Guide
Copyright
©
2013 SMC Networks Page 6
All Rights Reserved
I/M SMCGB10-Z rev. 1.0
8/2/2013
10 Defaulting the Detector
This step should only be performed by a qualified
service technician.
A. Remove the top cover from the SMCGB10-Z.
B. Remove the battery.
C. Press and hold the enrollment switch in the
RF circuit inside the SMCGB10-Z until you
replace the batteries.
D. Replace the battery while still pressing the
enrollment switch then release the switch.
The RF Module LED flashes three times to
signal the product is defaulted and not
paired with a Touchscreen.
E. Replace the top cover.
11 Viewing Zone Event History
To view event history:
A. Tap the Security widget on the Home screen.
B. Tap the History tab. The Zone Event History
shows the event history.
12 Disabling Zones
The system can bypass a zone, so the zone is not
monitored when the system is armed. This is
useful when a sensor is being repaired. You can
only change the Bypass state of a zone when the
system is disarmed.
The system continues to log the activity of
bypassed zones in the Event History (see "View
Zone Event History" on this page).
To bypass a zone:
A. With the system disarmed, tap the Security
app on the Home screen.
B. Tap the Turn Zone Off button for the smoke
alarm. The Turn Zone Off button changes to
Turn Zone On.
C. When the system is disarmed, the Security
Status header shows that some zones have
been bypassed.
13 Deleting from Touchscreen
Deleting a sensor from the premises removes it
from being monitored by the customer's system.
This is not the same as disabling (bypassing) a
sensor. You should delete a sensor only:
If the SMCGB10-Z is being removed from the
premises
To reset the product to factory default
settings by deleting the product and adding it
immediately.
To delete a product from the system:
A. Contact Customer Care to obtain the Premise
Passphrase for the current customer account.
B. Perform steps A through D in Step 6, "Adding
to Touchscreen." on page 4.
C. When the Technician Settings menu appears,
select Sensors & Zones > Delete a
Sensor/Zone. The Premise Passphrase
keyboard appears.
D. Enter the Premise Passphrase and click
Done. The currently installed
sensors/security zones appear.
E. Tap the zone you want to delete and follow
the instructions provided by the Touchscreen
to delete the sensor and security zone from
the current system.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SMC Networks SMCGB10-Z and is the answer not in the manual?

SMC Networks SMCGB10-Z Specifications

General IconGeneral
BrandSMC Networks
ModelSMCGB10-Z
CategoryAccessories
LanguageEnglish

Related product manuals