S Kit
1 to 8 stations:
EX500
1 to 12 stations:
EX250
T Kit
1 to 10 stations
F and P Kits
1 to 12 stations
6
Standard Specifications
Manifold Specifications
Valve specifications
Electrical
specifications
VQC1000/2000VQC4000
Single
Double
3-position
4-position
Single
Double
3-position
Valve Configuration
Fluid
Max. operating pressure
Max. operating pressure
Note 3)
Min. operating
pressure
Proof pressure
Ambient and fluid temperature
Lubrication
Manual override
Impact resistance/Vibration resistance
Enclosure
Rated coil voltage
Allowable voltage fluctuation
Coil insulation type
Power consumption (Current)
24VDC
Metal seal
0.1MPa
0.1MPa
0.15MPa
0.15MPa
Air/Inert gas
0.7MPa (High pressure type: 1.0MPa)
Note 4)
0.1MPa
1.0MPa (0.7MPa)
0.15MPa
1.5MPa
10° to 50°C
Note 1)
Not required
Push type/Locking type (tool required) optional
150/30 m/s²
Note 2)
Dust proof (conforms to IP67)
24VDC
±10% of rated voltage
Equivalent to B type
1W DC (42mA), 0.5W DC (21mA)
Rubber seal
0.15MPa
0.2MPa
0.15MPa
0.2MPa
0.2MPa
Note 1) Use dry air to prevent condensation at low temperatures.
Note 2) Impact resistance: No malfunction resulted from the impact test using a drop impact tester. The test was
performed one time each in the axial and right angle directions of the main valve and armature, for both
energized and de-energized states.
Vibration resistance: No malfunction occurred in a one-sweep test between 8.3 and 2000Hz. Test was
performed in the axial and right angle directions of the main valve and armature for both energized and
de-energized states.
Note 3) Values in ( ) are for the low wattage (0.5W) specification.
Note 4) Metal seal type only.
Series
F Kit: D-sub connector
P Kit: Flat ribbon cable
T Kit: Terminal block box
S Kit: Serial transmission
F Kit: D-sub connector
P Kit: Flat ribbon cable
T Kit: Terminal block box
S Kit: Serial transmission
Base model
VQC1000 VV5QC11-
VQC2000 VV5QC21-
T Kit: Terminal block box
S Kit: Serial transmission
VQC4000 VV5QC41-
Connection type
Piping specifications
Applicable
stations
Applicable
solenoid
valves
5-station
weight
(g)
Port
direction
Side
Port size
Note 1)
1, 3 (P, R)
C8 (for ø8)
Options
Direct outlet
with built-in
silencer
2, 4 (A, B)
C3 (for ø3.2)
C4 (for ø4)
C6 (for ø6)
M5 (M5 threads)
C8 (for ø8)
C10 (for ø10)
C12 (for ø12)
Rc 1/4
Rc 3/8
P: Rc 1/2
R: Rc 3/4
Rc 1/4
628
(Single)
759
(Double, 3P)
VQC100-5
VQC101-5
Note 2)
Side
Side
Bottom
C10 (for ø10)
Options
Direct outlet
with built-in
silencer
C4 (for ø4)
C6 (for ø6)
C8 (for ø8)
1051
(Single)
1144
(Double, 3P)
4150
S Kit
(without unit)
Solenoid
weight is not
included.
VQC200-5
VQC201-5
VQC400-5
VQC401-5
Note 1) One-touch fittings in inch sizes are also available.
Note 2) An optional specification for special wiring is available to increase the maximum number of stations.
T Kit
1 to 10 stations
( )
S Kit
1 to 16 stations
Min. operating
pressure
VQC
Base-Mounted Type
Plug-in Unit

Other manuals for SMC Networks VQC1000 Series