FAULT
DESCRIPTION
E7
Turbine flow-regulator malfunction
(for the relevant models only)
The appliance is not able to "measure" the amount
of water loaded accurately. Interrupt the program
and switch off the dishwasher. Switch the
dishwasher back on, program it again and start
the washing cycle. If the problem persists, contact
the after-sales service.
E8
Alternate washing system malfunction
Interrupt the program and switch off the dishwasher.
Switch the dishwasher back on, program it again and
start the washing cycle. If the problem persists,
contact the after-sales service.
E9
Water intake system malfunction
Contact the after-sales service.
Light off
Light on
Light flashing
If an alarm occurs the appliance interrupts the program in progress and
signals a fault.
Alarms E1, E2, E3, E4, E8 and E9 interrupt the current program
immediately.
The E5, E6 alarms interrupts the running program once the cause is
resolved, it will bring bach the execution of the program.
The alarm E7 is visualized at the end of the cycle that comes, however,
brought to the end since the operation of the dishwasher is not harmed.
To “reset” an alarm is necessary:
Open and close the door, or turn off and on the machine. At this point is
possible to program the dishwasher again.
If the malfunction persists, contact your authorised Service Centre.