12.2 Cable replacement
Should the supply cable need replacing,
remove the back guard by unscrewing the
screws to gain access to the terminal.
Replace the cable. The cable cross-
section must be no less than 1.5 mm² (3 x
1.5).
Make sure that the cables (for the oven or
any hob) follow the best route in order to
avoid any contact with the oven.
WARNING: The tightening torque of the screws of the terminal supply wires
must be 1.5 - 2 Nm.