3.4 Burner and nozzle characteristics table (Mod. 60 cm.)
Burner Rated
heating
capacity
(kW)
LPG G30 30 mbar
Nozzle
diameter
1/100 mm
Reduced
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary 1.0 50 350 73 71
Semi rapid 1.8 65 450 131 129
Triple crown 3.2 91 1500 233 229
Burner Rated
heating
capacity
(kW)
NATURAL GAS – G20 20 mbar
Nozzle diameter
1/100 mm
Reduced flowrate
(W)
Auxiliary 1.0 72 350
Semi rapid 1.8 97 450
Triple crown 3.5 133 1500
3.5 Arrangement of the burners on the hob (Mod. 60 cm.)
BURNERS
1.
Auxiliary
2.
Semi rapid
4 Triple crown