EasyManua.ls Logo

Smeg TR93GR - Page 47

Smeg TR93GR
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
103
EN
The nozzles not provided are available at Authorised Service Centres.
7 LPG G30/31 AUX SR R UR2
Rated heating capacity (kW) 1.0 1.8 3.0 4.0
Nozzle diameter (1/100 mm) 50 65 85 100
Pre-chamber (printed on nozzle) --- -
Reduced flow rate (W) 400 500 800 1300
Rated flow rate G30 (g/h) 73 131 218 291
Rated flow rate G31 (g/h) 71 129 214 286
8 LPG G30/31 AUX SR R UR2
Rated heating capacity (kW) 1.1 1.9 3.0 4.2
Nozzle diameter (1/100 mm) 50 65 81 95
Pre-chamber (printed on nozzle) --- -
Reduced flow rate (W) 450 550 900 1500
Rated flow rate G30 (g/h) 80 138 218 305
Rated flow rate G31 (g/h) 79 136 214 300
9 LPG G30/31 AUX SR R UR2
Rated heating capacity (kW) 1.0 1.8 3.0 4.1
Nozzle diameter (1/100 mm) 43 58 74 80
Pre-chamber (printed on nozzle) (H2) (M) (Z) (F4)
Reduced flow rate (W) 400 500 1000 1500
Rated flow rate G30 (g/h) 73 131 218 298
Rated flow rate G31 (g/h) 71 129 214 293
10 Town gas G110 AUX SR R UR2
Rated heating capacity (kW) 1.0 1.75 2.8 3.3
Nozzle diameter (1/100 mm) 145 185 260 340
Pre-chamber (printed on nozzle) /8 /2 /3 0190
Reduced flow rate (W) 400 500 800 1000