Installation
104
5.3 Positioning
This appliance may be installed next to
walls, one of which must be higher than the
worktop, at a minimum distance of X mm
from the side of the appliance, as shown in
figures “A” and “C” relative to the
installation classes.
Any wall units positioned above the
worktop of the appliance must be at a
minimum distance of at least Y mm. If a
hood is installed above the hob, refer to the
hood instruction manual to ensure the
correct clearance is left.
Depending on the type of installation, this
appliance belongs to classes:
A - Class 1
(Free-standing appliance)
Heavy appliance
Crushing hazard
• Position the appliance into the cabinet
cut-out with the help of a second person.
Pressure on the open door
Risk of damage to the appliance
• Never use the oven door to lever the
appliance into place when fitting.
Avoid exerting too much pressure on the
door when open.
Heat production during appliance
operation
Risk of fire
• Veneers, adhesives or plastic coatings
on adjacent furniture should be
temperature-resistant (not less than
90 °C).
X 150 mm
Y 750 mm