4. INSTALLATION
S.\\I~"
by Dometic
GROUP
S."I~"
by
Dometic
GROUP
4. INSTALLATION
~
TOTAL
NOMINAL
GAS
CONSUMPTION
MJ/h
2,5kg/h
OUTPUT
OFTHE
REGULATOR
Grill
Oven
NQ
MJ/h
NQ
MJ/h
2,75 kPa
AUXILIARY
047mm
NQ
MJ/h
PRESSURE
NOMINAL
GAS
CONSUMPTION
SEMI-RAPID
062mm
NQ
MJ/h
WARNING
The
appliance
is
not
suitable
for
connection
with
a
hose
assembly.
WARNING
A
manual
shut-off
valve
shall
be
provided
on
the
inlet
connection
of
the
appliance.
The
valve
shall
be
accessible
for
operation
and
firmly
fixed.
GAS
Model
UNIVERSAL
LPG
WARNING
WARNING
CU311 2
5.9
2
3.8 I
5.2
I 3.8 24.6
CU311M 2
5.9
2
3.8 I
5.2
1 3.8 24.6
CU333 I 5.9 1
3.8
I 5.2 I 3.8 14.9
CU333M I
5.9 1 3.8 I 5.2 I 3.8 14.9
CU335 2 5.9 I
3.8 I 5.2 I 3.8 20.8
CU335M 2 5.9 I
3.8
I 5.2
I
3.8 20.8
CU401
3 5.9 I 3.8 I 5.2 1 3.8 30.5
CU40lPE
2
5.9
I
3.8 I 5.2 I 3.8 24.6
CU402
3 5.9
I
3.8 I
5.2 26.7
CU402PE 2 5.9 I
3.8
I 5.2 20.8
CU403
3 5.9 I 3.8 21.5
CU403PE 2 5.9 I
3.8 15.6
F0311
I 5.2 I 3.8 5.2
M08103
I 5.9 2
3.8
13.5
M08123
I 5.9 2
3.8 13.5
PI8002 I 5.9 1
3.8
9.7
PI8022 I 5.9 I 3.8 9.7
PI8003 2 5.9 I
3.8
15.6
PI8023 2 5.9 I 3.8 15.6
VN555 I 5.2 5.2
Below
are
the
gas characteristics for which
the
appliance
is
set
(given also on
the
appliance data plate). A
pressure
reducer
suitable for
the
type
of
gas used must
be
connected
between
the
gas cylinder and
the
appliance:
Between
the
top
part
of
the
burners
and cabinets and 1
or
shelves fitted above
the
hotplate.
From
the
sides
of
the
appliance and vertical walls.
From
the
top
side
to
the
cabinets and 1
or
shelves fitted above
the
appliance.
From
the
external edge
of
the
burner
head
nearest
to
a side and 1
or
back wall.
INSTALLATION
WARNING
WARNING
The
appliance
must
fitted
at
an
appropriate
and
safe
distance
from
flammable
materials.
This
appliance
is
not
connected
to
a flue
terminal
which
discharges
the
product
of
combustion
to
the
outside.
Any
enclosed
space
in
which
the
appliance
is
installed
must
therefore
be
provided
with
permanent
ventilation
in
accordance
with
relevant
federal
and
state
regulations
in
force,
and
the
requirements
of
gas
installations
with
particular
attention
being
paid
to
the
matter
of
room
ventilation.
WARNING
This
appliance
shall
be
installed
only
by
authorised
persons
and
in
accordance
with
the
manufacturer's
installation
instructions,
local
gas
fitting
regulations,
municipal
building
codes,
electrical
wiring
regulations,AS
5601ยท2004
- Gas Installations
and
any
other
statutory
regulations.
WARNING
Dimensions
of
the
appliance
170mm
100mm
WARNING
600 mm
200 mm
WARNING
WARNING
Dimensions
of
fitting
cavity
Cut
out
a hole
in
the
cabinet as illustrated
in
FIG.
5 - PG.
21
size
will
depend
on
appliance model.
The
cabinet must be appropriately
constructed
and aligned horizontally with
the
worktop
and with
the
unit.
The
cabinet
aperture
must be perfectly squared and aligned.
If
there
are
apertures
for cabinet ventilation,
prevent flammable materials from entering
these.
4.3
Gas
connection
4.2
Fitting
cavity
Minimum allowable distances from walls (FIG.4 - PG. 20)
For
the
CU
...,
FO
...
and
VN555
models,
the
cavity
that
the
appliance
is
built
into
must
be
completely
sealed
off.
It
is
important
that
the
inside
panels
of
the
cavity
are
WARNING
completely
sealed
and
do
not
communicate
with
adjoining
cavities
or
the
outside.
The
openings
in
the
cavity
that
allow
access
to
the
gas
and
electric
connections
should
be
sealed
with
rubber
or
foam.
The
gas connection
(114
BSPT
female)
is
located
at
the
rear for models CU
...
, FO
...
and for model VN555,
whereas
it
is
on
the
bottom
for models
Pl.
..
and MO
...
The
electric connection
is
located
at
the
rear
for models CU
...
, FO
...
and for model VN555,
whereas
it
is
on
the
bottom
for models
PI...
and MO
...
(consult
chapter
4.4 Electric connection
to
see
whether
the
appliance
needs this connection).
The
overall dimensions
are
illustrated
in
FIG.5 PG.
21
with
the
cavity diagrams.
The
overall dimensions include
the
trivet (pan support), control knobs, handles and gas connection.
4.
4.1
12
13