4.
INSTALLATION
Si\\n\'
by
Dometic
GROUP
Ni\\U\'
by
Dometic
GROUP
4.
INSTALLATION
U
BURNER
INJECTOR
ORIFICE
(mm)
STAMPED
N!l
AUXILIARY
(0
47mm)
0.57
57
SEMI-RAPID
(0
62mm)
0.72 72
OVEN
0.57
57
GRILL
0.67 67
The connection of the
gas
pipe
to
the appliance (1/4
BSPT
female) must be made with a
rigid
metal pipe.The
pipe
work
and fittings
shall
be free from defects and of
an
approved type.
Once
installed.
the
installation must be checked for leaks
by
means of
an
approved testing method.
Do
not
use a solution of soap and water.
WARNING
Never
use
a
naked
flame
to
check
for
gas
leaks.
The
supply
cord
must
be
positioned
in
such
a
way
that
it
never
reaches
a
temperature
of
75°C
above
ambient
in
any
point.
The
plug
must
be
easy
to
access
after
installation.
Always
disconnect
electrical
power
before
working
on
or
servicing
the)
appliance.
For connecting
to
the mains power supply use a socket.
If
the supply cord (H05RR-F 3x0,75mm
2
)
is
damaged. it must be replaced
by
the manufacturer
or
its service
agent
or
a similarly qualified person
in
order
to
avoid a hazard.
4.5
Fixture
CAUTION
This
appliance
is
to
be
fixed
and
secured
to
the
cabinet
as
described
in FIG. 6 -
PG.
25.
CAUTION
WARNING
4.6
Testing
(before
leaving)
4.4
Electric
connection
Low
voltage
I2V "-='"
This chapter concerns only models marked
12
V "-='" on
the
appliance data plate.
CAUTION
Ignite
all
burners both individually and concurrently
to
ensure
correct
operation of
gas
valves. burners and
ignition.Turn gas taps
to
low flame position and observe stability of the flame for each burner individually and
concurrently. Ensure
correct
operation of the flame failure protection.
Depending on
the
type of
gas
used.
the
appearance of
the
flame
is
as
follows:
Propane:
flame with blue centre and well-defined contour.
Butane:
flame with light yellow tips when igniting
the
burner. gradually intensifying
as
the
burner heats.
In
case
the
appliance
fails
to
operate
correctly
after
all
checks
have
been
carried
out,
shut
off
the
gas
supply
at
the
main
gas
tap
and
refer
to
the
authorized
service
CAUTION
provider
in
your
area.
When satisfied with
the
appliance. please instruct the user on
the
correct
method of operation.
WARNING
Absolutely
do
not
connect
the
appliance
to
the
mains
voltage
(230
V-),
this
would
destroy
the
components
and
cause
a
hazard
for
the
user.
CAUTION
This
appliance
must
be
connected
to
a
12V
"-='"
source.The
circuit
must
be
protected
by a
fuse
of
no
more
than
3
Ampere.
Ensure
that
the
polarity
of
the
connection
is
correct!
CAUTION
WARNING
To
connect the appliance use a
1.5
mm
2
double red and black wire and wire
to
the terminal junction box
located at
the
rear of the appliance with the wording "+
12
V"-="'- ".The red terminal
is
the
positive pole and
the black terminal
is
the
negative pole.
High
voltage
230-240
V-
This chapter refers only
to
the models listed
in
the table below.
Model
CU40 I
PE
- CU402PE - CU403PE
Nominal
voltage
230-240V-
Nominal
power
800W
4.6.1
Test
point
For
models
PI...
MO
...
CU
...
The
test
point
is
supplied loose with the appliance (see picture
in
FIG.
7
PG.
29). Remove one burner head. the
injector and screw
in
test
point fitting. The pressure
is
measured with the relevant burner
gas
valve
on
high
flame and with
an
inlet pressure of 2.75
kPa.
For
models
FO
...
The
test
point
is
fitted on the
main
gas
pipe. Remove
the
front plastic plaque (see picture
in
FIG.8
PG.
29) and
remove the screw.The pressure
is
measured with
an
inlet pressure of 2.75
kPa.
In
these models there
is
an
electric plate
in
the hotplate.
WARNING
WARNING
.
When
connecting
direct
to
the
mains
supply,
it
is
necessary
to
install
a
circuit
breaker
which
allows
for
disconnecting
and
isolating
the
appliance
from
the
mains
in
the
event
of
overvoltage
III
conforming
to
installation
regulations.
For
modelsVN555
The
test
point
is
fitted on
the
main
gas
pipe. Remove the screw. The pressure
is
measured with
an
inlet
pressure of 2.75
kPa
.
14
15