2-12
IInnssttaallllaattiioonn
aanndd
OOppeerraattiioonn
Evacuating A/C System
Use this procedure to remove air and moisture from vehicle A/C
system.
33
33
If gauges indicate pressure, recover refrigerant from
service hoses before proceeding. Refer to Evacuating
Service Hoses in this Chapter.
1. Open the following:
Red service hose hand valve or coupler,
Blue service hose hand valve or coupler,
High side manifold hand valve, and
Low side manifold hand valve.
2. Turn Compressor switch ON.
3. Turn vacuum/recycle valve to VACUUM.
Low side manifold gauge shows vacuum increasing.
33
33
Follow manufacturer recommendations for evacuation
time, usually at least 30 minutes.
4. Close manifold hand valves when desired vacuum and
duration have been reached.
5. Turn Vacuum/Recycle valve OFF.
6. Turn compressor switch OFF.
COMPRESSOR ON indicator goes out and compressor
stops running.
7. Monitor low side pressure for 5 minutes.
Any rise in vacuum indicates a leak in vehicle system.
33
33
If source of leak cannot be determined, partially charge
system and perform leak test using electronic leak
detector.
8. When leak is identified, repeat Recover/Recycle
proceedure, repair leak and attempt Evacuation
proceedure again.
Evacuation is complete.