3-9
MMaaiinntteennaannccee
Troubleshooting
Symptom Possible Cause Remedy
Machine does not turn on Power cord not plugged in Plug in cord
No power in AC outlet Check power source
Refrigerant not being Hand valves not open Open hand valves
removed from vehicle
Recovery tank full. Change tank or Charge
refrigerant
Excessive purging of Fitting(s) not properly Tighten fitting(s) finger tight
non-condensables connected to master filter
Leaky service hose or Tighten fittings or
adaptor connection drawing replace seals in
in air finger tight fittings
Does not charge Blue hand valve on recovery Open blue hand valve
tank not open
Fitting not properly Tighten fitting finger tight
connected to recovery tank
No refrigerant in tank Fill tank with refrigerant
Machine does not draw Loose hose connection Tighten loose hose
a vacuum connections
Oil drain valve open Close oil drain valve
Hissing noise from oil Oil drain valve open Close oil drain valve
separator during recycle
and/or vacuum mode
Refrigerant losses from Leaky hand valve(s) on tank Make sure hand
tank on scale over time valves are either open
completely(CCW) or closed
completely (CW) and
leak test
Leaky fitting(s) Oil seal with refrigerant oil
and reconnect OR,
replace fitting, oil seal
and reconnect
Long recycle times System being recycled is – Heat A/C system by
cold and has components that running engine with
hold a substantial amount of A/C OFF and keep hood
liquid refrigerant closed as much as practical
to hold in heat