11
Push
Buttons
LCD
Display
Rotary
Switch
Input
Jacks
10
j. Capacitance
Range Resolution Accuracy Overload Protection
40nF 0.01nF 600V DC or
400nF 0.1nF AC Peak
4uF 0.001nF ±(3.0% +10 digits)
40uF 0.01uF
400uF 0.1uF
4000uF 1uF ±(7.0% +10 digits)
k. Frequency (Hz)
Range Resolution Accuracy Overload Protection
10Hz 0.01Hz 600V DC or
100Hz 0.1Hz AC Peak
1KHz 0.001KHz ±(0.05% +3 digits)
10KHz 0.01KHz
100KHz 0.1KHz
1MHz 0.001MHz
10MHz 0.01MHz
l. General Specifications
Max. Volt. between 1000V
any Input and Ground
Fuse Protection mA: 0.5Amp/600VAC A: 10Amp/600VAC
Display Type 4,000 Count, 2 times per second update
Operating Temp. 0° to 40°C (32° to 104°F)
Storage Temp. -10° to 50°C (14° to 122°F)
Relative Humidity 0% to 80%
Power Supply 2 Each 1.5 Volt “AA” Batteries
Battery Life 200 hrs. Typical
Size (H x L x W) 1.3in x 3.4in x 7.4in (33mm x 86mm x 187mm)
Weight 340g (12oz)
D. MEASUREMENT TECHNIQUES
1. Controls and Functions:
a. Push Buttons
Activates manual ranging. Hold in for 3 seconds
to return to autorange.
Activates the Min/Max mode. APO (Auto Power
Off) is disabled in this function. Hold in for 3
seconds to deactivate.
Toggles the ACV or ACA measurement mode to
Hz or Duty Cycle mode.
Displays value as a difference of reference value.
Toggles between AC or DC on the mV function
and all current functions.
Toggles between continuity buzzer or diode test
on the resistance function.
Holds the reading on the display until the button
is pushed a second time.
RANGE
REC
Hz/DUTY
REL
AC/DC
/
HOLD

Related product manuals