EasyManua.ls Logo

Snap-On EEDM504D - Measuring AC Voltage (ACV); Measuring DC Current (DCA)

Snap-On EEDM504D
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1514
c. MEASURING DC AMPS
CAUTION!
Do not attempt to make a current measurement with
the test leads connected in parallel with circuit to be
tested. Test leads must be connected in series with
the circuit.
W
ARNING!
Do not attempt to make a current measurement of
circuits with more than 600V present. Instrument
damage and /or personal injury may result.
Instrument set-up:
FUNCTION BLACK RED MINIMUM MAXIMUM
TEST LEAD TEST LEAD READING READING
40µA COM µAmA 0.01µA 40µA
µA COM µAmA 0.1µA 4000µA
mA COM µAmA 0.01mA 400mA
10A COM A 0.001A 10.00A
Measurement Procedure:
1. Disconnect power to circuit to be measured.
2. Plug the black test lead into the COM input jack.
3. Plug the red test lead into the µAmA or A input jack
depending on the value of current to be measured.
4. Set the rotary switch to the 40µA, µA, mA, or A
function.
5. Connect test leads in series to circuit to be measured.
6. Reconnect power to the circuit to be measured.
7. Read the current on the EEDM504D.
Optional Functions:
b. MEASURING AC VOLTS
CAUTION!
Do not attempt to make a voltage measurement if a
test lead is plugged in the A or µmA input jack.
Instrument damage and/or personal injury may
result.
W
ARNING!
Do not attempt to make a voltage measurement of
more than 750V or of a voltage level that is
unknown.
Instrument set-up:
FUNCTION BLACK RED MINIMUM MAXIMUM
TEST LEAD TEST LEAD READING READING
COM V
W
Hz 0.001V 750V
Measurement Procedure:
1. Disconnect power to the circuit to be measured.
2. Plug the black test lead into the COM input jack.
3. Plug the red test lead into the V
W
Hz input jack.
4. Set the rotary switch to the function depending on
the voltage to be measured.
5. Connect the test leads to the circuit to be measured.
6. Reconnect power to the circuit to be measured.
7. Read the voltage on the EEDM504D.
Optional Functions:
RANGE
REC
REL
HOLD
Manually select the appropriate range.
Activate MIN/MAX record mode (page 22).
Scroll between Hz, Duty, and Volts.
Activate REL mode (page 22).
Freeze the reading on the LCD.
Hz/DUTY
RANGE
REC
REL
HOLD
Manually select the appropriate range.
Activate MIN/MAX record mode (page 22).
Activate REL mode (page 22).
Freeze the reading on the LCD.