3
2.0 SPECIFICATIONS
2.1 Electrical Data
Current ranges : 20A / 60A AC PEAK or DC
Measuring range : +/- 20A / 60A
Output sensitivity : 100mV / 10mV/A
Accuracy (20A Range) : +/- 1% of reading +/- 5mA
Accuracy (60A Range) : +/- 2% of reading +/- 50mA
Resolution : +/- 1mA / 10mA
Load impedance : >10kOhm and ≤ 100pF
Conductor position
Sensitivity : +/- 1% relative to center
reading
Frequency range : DC to 50kHz (-3dB)
Temperature coefficient : +/- 0.1% of reading / °C
Power supply : 9V Alkaline,
PP3/MN1604
: 50 Hours, low battery
indicator
Working voltage (see Safety Standards section)
: 150V AC (RMS) or DC.
2.2 General Data
Maximum conductor size : 12mm diameter
Output connection : 4mm safety plugs
Output zero : Auto zero via push button
Cable length : 1.5 meters
Operating temperature
range : : 0 to +50 °C / 32 to +122 ° F
Storage temperature range: -20 to +85 °C / -4 to +1 85 °F
Operating humidity : 15% to 85% (non
condensing)
Weight : 250g / 0.55lb