8
Operating Instructions BC5500B
A—Coarse Rate Range Switch
Selects volts for charge. Range settings are:
—6LO,
— 6HI,
—12LO, or
— 12HI.
B—Fine Rate Range Switch
Selects volts for charge. Range settings are:
—LO,
— 2 REG,
— 3 HYBRID, or
— HI MAIN FREE.
C—Ammeter Meter
Displays amps, 0 to 100 ADC, flowing from charger into battery.
D—Length of Charge Timer
Selects charger power mode and charge duration with manual
or automatic shut-off functions.
• OFF electrically shuts off power to the charger.
— Select before connecting or disconnecting power cord or
any leads.
• HOLD powers charger until OFF is manually selected.
— Select when desired charge time exceeds 120 minutes.
Charger does not turn off automatically when this function
is selected.
• CHARGE TIME is number of minutes the charger operates
before automatically shut-off. Charger shuts off automatically
after number of minutes selected lapse when this function is
selected.
— Up to 120 minutes can be selected. Increase or
decrease charge time as needed by selecting new time.
✓✓
✓✓
The charger automatically shuts off when the charge
time reaches zero.