MODEL
Heating medium
Water, coolant
125 W
12 V or 24 V
10.5 V or 21V
(under-voltage protection will shut down the units when the voltage drops to this value)
16 V or 32V
(over- voltage protection will shut down the units when the voltage riches this value)
Max.2.0bar
1400L/h (When operating pressure is 0.14bar)
500 L/h
-40 - 80
-40 - 85
Approx 5kg
Weight (including controller
and water pump except oil pump)
Allowable
ambient
temperature
Operating
Storage
Minimum water through-put capacity
Water flow of water pumu
Allowable operation pressure
Operation
voltage range
Minimum voltage
Maximum voltage
Rated voltage (V)
Power
consumption
(W)
Operating
Start up
Heat flow control
Heating output (kW)
Fuel consumption (L/h)
Fuel
TECHNICAL SPECIFICATIONS& DIMENSION
Super high
5
0.61
Diesel
51
High
4
0.49
Middle
3.3
0.4
Low
3
0.37
43
40 37
Please note:
Listed technical data is subject to the tolerances of 10 %. Allowable Ambient
temperature is 20
Dimension
Combustion Air Intake
The heater combustion air shall NOT be taken from passenger compartment, cargo space or
operator (driver) cabin. The air intake shall be protected from possible water intake into
combustion chamber, and cannot be blocked by any object at any time.
Please Note:
Failure to comply with the regulations, safety instructions, repairs done by unauthorized
person, use of aftermarket parts voids warranty and relieves manufacture, distributors,
dealers, and installation technicians from any and all liabilities.
Disconnect vehicle battery power before commencing repair or performing heater maintenance.
Before beginning any work on the heater, switch the heater OFF and let all hot parts cool down.
The heater shall NOT be used in: poor ventilated rooms, garages, shops, multi-storage car
park, etc. Use heater only in open, well ventilated areas.
Use of aftermarket parts is strictly prohibited unless authorized by the manufacturer.
Installation and operation of the heater shall comply with statutory regulations, safety
instructions and specifications as stated in the installation and operating instructions. Extreme
precaution shall be taken when installing and maintaining electrical wiring, fuel supply,
combustion air and exhaust system.
Unauthorized persons are not allowed to do any repairs or maintenance.
Debris or any other remains shall be removed and cleaned before reinstalling the heater into
another vehicle.
The heater shall NOT be used in hazardous places such as but not limited to: fuel depots,
carbon storage, timber warehouses, granaries and any other places where combustible or
flammable vapor or dust may be present.
Heater must be switched OFF during refueling.
The heater shall be installed in a spacious compartment. Fuel canisters, oil cans, spray cans,
gas cartridges, fire extinguisher, cleaning rags, clothing, papers, or any combustible or
flammable materials shall NOT be stored or transported on or next to the heater.
Defective or burned fuses shall be replaced only with same type and same rating fuses.
In the event of a fuel leak; turn OFF the heater immediately, disconnect and cap off fuel line.
The leak shall be repaired by a professional, authorized technician.
Use only coolant liquids that are permitted by the vehicle manufacturer. Use of other coolants
might damage the engine or heater.
Please note:
Do NOT prematurely shut down the heater by disconnecting the power unless required
to do so by an emergency.
Warning:
Carbon monoxide monitoring sensor with alarm shall be installed in all passenger
compartments, operator or driver cabin, and sleeper berth.
SAFETY INSTRUCTIONS AND OPERATION
SNUGGER
04
SNUGGER
03
SNUGGER
SS5000 WATER HEATER
281
20
10440
90
98
29
60
155
295
24
6-M8
239
142