DIPSwitches
Set the circuit breaker rating DIP switches (see
Figure 12
).
Figure 12: Safety Switch with EV Charger internal interfaces
To set the circuit breaker ratings:
Use the circuit breaker rating DIP switches to set circuit breaker ratings.
Circuit Breaker Rating DIPSwitch Settings
Maximum Allowed
AC Current from Grid
1 (left) 2 (right)
20 A OFF OFF 16 A
30 A ON OFF 24 A
40 A OFF ON 32A
50 A ON ON 40 A
Buzzer
The EV charger includes a buzzer with the following indications:
Event Buzzer Indication
Connected to EV 1 short beep
Charging starts 2 short beeps + 1 long beep
Error 5 beeps
Opening Conduit Drill Guides
This step may be performed before or after mounting the inverter.
Chapter 3: Installing the Inverter 33