Operation mode Description LCD display
Line Mode
The unit will provide output
power from the mains. It will
also charge the battery at
line mode.
If “SUB” (solar first) is selected as output
source priority and solar energy is not sufficient
to provide the load, solar energy and the utility
will provide the loads and charge the battery at
the same time.
If either “SUB” (solar first) or “SBU” is selected
as output source priority and battery is not
connected, solar energy and the utility will
provide the loads.
Power from utility.
Battery Mode
The unit will provide output
power from battery and/or
PV power.
Power from battery and PV energy.
PV energy will supply power to the loads and
charge battery at the same time. No utility is
available.
Power from battery only.