EasyManua.ls Logo

SolarPower24 SP24 - User Manual

Default Icon
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SP24 AXPERT MAX 8KW TWIN
SOLAR INVERTER / CHARGER
Version: 1.0
User Manual
Question and Answer IconNeed help?

Do you have a question about the SolarPower24 SP24 and is the answer not in the manual?

Summary

About This Manual

Purpose

Describes the manual's purpose for assembly, installation, operation, and troubleshooting.

Scope

Provides safety and installation guidelines, plus tool and wiring information.

Safety Instructions

Contains important safety and operating instructions for user reference.

Introduction

Features

Lists the key features and functionalities of the multi-function inverter/charger.

Basic System Architecture

Shows a basic application illustration and required devices for a complete running system.

Installation

Unpacking and Inspection

Instructions to inspect the unit and package contents for any damage before installation.

Preparation

Steps to prepare the unit for wiring by removing the bottom cover.

Mounting the Unit

Guidelines for selecting a suitable, safe location and proper mounting orientation for the unit.

Battery Connection

Detailed steps and requirements for safely and securely connecting the battery terminals.

AC Input;Output Connection

Procedures for safely connecting the AC input and output power sources to the unit.

PV Connection

Steps and guidelines for connecting photovoltaic modules to the inverter's input connectors.

Final Assembly

Final steps to reconnect cables and secure the bottom cover after all wiring is completed.

Remote Display Panel Installation

Instructions on how to detach, mount, and connect the LCD module remotely.

DC Output Connectors

Details on DC output connectors used for providing emergency power to various equipment.

Communication Connection

Instructions for establishing serial and Wi-Fi communication connections for monitoring and control.

Dry Contact Signal

Explanation of the dry contact signal used to alert external devices of battery warning levels.

BMS Communication

Recommendations for connecting to Lithium-Ion battery banks using the BMS communication interface.

Operation

Power ON;OFF

Procedure for turning the unit on and off using the power on/off switch.

Inverter Turn-on

Describes the initial welcome light show and the inverter's initialization sequence.

Operation and Display Panel

Overview of the LCD display panel, status indicators, and function keys for unit operation.

LCD Display Icons

Explanation of the meaning and function of various icons displayed on the LCD screen.

Battery Information

Information displayed on the LCD regarding battery level and charging status.

Load Information

Information on the LCD indicating load level, overload status, and power consumption.

Mode Operation Information

Explanation of icons representing different operational modes and system statuses.

LCD Setting

Guide to navigating and configuring various system settings via the LCD panel interface.

Function Setting

Overview of function keys and special functions like USB OTG and timer settings.

USB Function Setting

Instructions on using the USB port for firmware upgrades, data log export, and parameter management.

Timer Setting for Output Source Priority

Setting timers to configure the daily output source priority of the inverter.

Timer Setting for the Charger Source Priority

Setting timers to configure the daily charger source priority of the inverter.

Operating Mode Description

Faults Reference Code

Warning Indicator

Battery Equalization

How to Apply Equalization Function

Steps to enable and apply the battery equalization function via LCD settings.

When to Equalize

Conditions and timing for initiating the battery equalization process.

Equalize charging time and timeout

Explanation of duration, timeout, and voltage parameters for the equalization process.

Specifications

Trouble Shooting

Appendix I: Parallel function

Introduction

Overview of parallel operation capabilities for single-phase and three-phase systems.

Mounting the Unit

Guidelines for mounting multiple units in parallel, ensuring proper airflow and level installation.

Wiring Connection

Recommended cable sizes and connection procedures for parallel battery and AC wiring.

Support 3-phase equipment

Configurations for supporting three-phase equipment using multiple inverters in various phase arrangements.

PV Connection

Instructions for connecting PV modules to inverters in parallel configurations.

LCD Setting and Display

How to configure LCD settings for parallel operation modes such as single, PAL, and 3-phase.

Commissioning

Procedures for commissioning parallel systems, covering single and three-phase setups.

Appendix II: BMS Communication Installation

Introduction

Information on using RJ45 cables for BMS communication with lithium batteries.

Pin Assignment for BMS Communication Port

Details the pin assignments for the BMS communication port on the inverter.

Lithium Battery Communication Configuration

Steps for configuring lithium battery communication and setting unique IDs for parallel operation.

Installation and Operation

Steps for installing and operating lithium battery systems with the inverter.

Appendix III: The Wi-Fi Operation Guide in Remote Panel

Introduction

Overview of the Wi-Fi module and WatchPower APP for remote monitoring and control.

Download and Install WatchPower App

Instructions for downloading and installing the WatchPower mobile application on smart devices.

Initial Setup for WatchPower App

Steps for registering and configuring the WatchPower App for initial use and connection.

Login and APP Main Function

Logging into the app and understanding its main functions like overview and device status.

Parameter Setting via App

How to access and modify inverter parameters using the WatchPower mobile application.

SolarPower24 SP24 Specifications

General IconGeneral
CategoryInverter
ModelSP24
Rated Power2400W
Input Voltage24V DC
Efficiency90%
WaveformPure Sine Wave
Peak Power4800W
Output Frequency60Hz
Protection FeaturesOverload, Short Circuit
CoolingFan
Operating Temperature-20°C to 50°C