EasyManua.ls Logo

SolarPower24 SP24 - Page 48

Default Icon
81 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
46
Solarpower24.it by Barba S.r.l. – via Locchi, 3F – 47122-Forlì – Italia
Tel/What’s up +39 05431995799 – web www.solarpower24.it – email solarpower24@solarpower24.it
Table 2 Inverter Mode Specifications
MODEL 8KW
Rated Output Power
8000W
Output Voltage Waveform Pure Sine Wave
Output Voltage Regulation 230Vac±5%
Output Frequency 60Hz or 50Hz
Peak Efficiency 93%
Overload Protection 100ms@≥205% load;5s@≥150% load; 10s@110%~150% load
Surge Capacity 2* rated power for 5 seconds
Optional 12V DC Output
DC Output 12 VDC ± 7%, 100W
High DC Cut-off Voltage 66Vdc
Low DC Cut-off Voltage 44Vdc
Nominal DC Input Voltage 48Vdc
Cold Start Voltage 46.0Vdc
Low DC Warning Voltage
@ load < 20%
46.0Vdc
@ 20% ≤ load < 50%
42.8Vdc
@ load ≥ 50%
40.4Vdc
Low DC Warning Return Voltage
@ load < 20%
48.0Vdc
@ 20% ≤ load < 50%
44.8Vdc
@ load ≥ 50%
42.4Vdc
Low DC Cut-off Voltage
@ load < 20%
44.0Vdc
@ 20% ≤ load < 50%
40.8Vdc
@ load ≥ 50%
38.4Vdc
High DC Recovery Voltage 64Vdc
High DC Cut-off Voltage 66Vdc
DC Voltage Accuracy +/-0.3V@ no load
THDV <5% for linear load,<10% for non-linear load @ nominal voltage
DC Offset
100mV