WARNING – Risk of Electric Shock. Connect only to a branch circuit protected by a ground-fault circuit-interrupter (GFCI).
Contact a qualified electrician if you cannot verify that the circuit is protected by a GFCI.
The unit must be connected only to a supply circuit that is protected by a ground-fault circuit-interrupter (GFCI). Such a GFCI
should be provided by the installer and should be tested on a routine basis. To test the GFCI, push the test button. The GFCI
should interrupt power. Push the reset button. Power should be restored. If the GFCI fails to operate in this manner, the GFCI is
defective. If the GFCI interrupts power to the pump without the test button being pushed, a ground current is flowing, indicating
the possibility of an electric shock. Do not use this pump. Disconnect the pump and have the problem corrected by a qualified
service representative before using.
WARNING - To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times.
CAUTION - This product should be installed by a professional service technician or similar person who is qualified in electrical
equipment installation. Improper installation and/or operation could cause serious personal injury, property damage or death.
Improper installation and/or operation will void the warranty.
CAUTION - To reduce the risk of personal injury the power supply must be installed on and wired to the load side of the time clock,
electronically controlled switch, or relay load side, so that it will receive power only when the pool pump is on. The Power supply
should never be energized when water is not flowing through the unit.
WARNING - ELECTRIC SHOCK - Disconnect all AC power during installation or performing any service work.
CAUTION - To prevent possible fire or electrical shock, use only replacement lamp specified by the manufacturer.
CAUTION - Do not use system if cord is damaged or frayed.
CAUTION - Lamps and quartz sleeves are made of glass and are extremely delicate. Care should be taken when handling or
replacing these components. Wear cotton gloves when handling lamps or sleeves. Hold lamps by the ends only. Never touch
the glass with bare hands. Wipe any fingerprints from lamps and sleeves with rubbing alcohol.
CAUTION - This device is for use on swimming pools less then 40,000 gallons. Do not use this device for potable (drinking) water
sanitization.
DANGER - ULTRAVIOLET RADIATION. Disconnect Power Before Replacing Lamp . This device contains an ultraviolet lamp
that can cause discomfort, irritation and damage to the eyes if viewing occurs while device is in operation. Prolonged exposure
to the eyes can cause serious injury to the eyes, including blindness. DO NOT DIRECTLY VIEW UV LAMP WHILE THE
DEVICE IS IN OPERATION. LAMP FUNCTION CAN BE VIEWED THROUGH QUARTZ VIEW CAP SAFELY.
ENVIRONMENTAL NOTICE - Hg-Lamp CONTAINS MERCURY. Manage in accordance with disposal laws. See:
www.lamprecycle.org
Specifications:
Max Pool Size: Pools up to 40,000 Gallons
Shipping Weight: 16 pounds
Connections: Two inch pipe connections on manifold with two inch unions included
Location Requirements: Power supply is wall mounted near the manifold and wired to the
same source power as the pump. Cord length between power supply and manifold is 9 Feet.
Input Power: 120/240VAC
Power Consumption: 60 Watt max.
Max Operating Pressure: 50 psi
Operating Flow Range: up to120 GPM
Lamp: 13,000 hour life expectancy
SAFETY INSTRUCTIONS
2
SAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS