V200116
Air conditioner must be upright for 24 hours prior to operating.
This ensures that the compressor will function as intended.
Model
WS1-06E-02 6,200 BTU
WS1-08E-02 8,000 BTU
WS1-10E-02 10,200 BTU
WS1-12E2-02 12,000 BTU
Electronic Window Air Conditioner
Operating Instructions
AIR CONDITIONER
2MF3
File No. SA 44822
Question and Answer IconNeed help?

Do you have a question about the Soleus Air WS1-06E-02 and is the answer not in the manual?

Summary

Purchase Information

Safety Precautions

Essential safety guidelines and warnings for using the air conditioner to prevent hazards.

Power Cord and Plug

Testing the LCDI Plug

Procedure to test the functionality of the Leakage Current Detection and Interruption (LCDI) plug.

Power Cord Warnings

Critical warnings regarding the proper and safe use of the power cord and plug.

Package Contents

Specifications

Electrical Safety

Power Cord Safety Warning

Warning against improper use of the power cord, including cutting or bypassing the grounding prong.

Disclaimer

Installation

Window Preparation

Instructions for preparing the window to ensure proper fit and installation of the air conditioner.

Storm Window Requirements

Guidance on adjusting for storm windows to ensure proper drainage and tilt.

Pre-Installation Checks

Steps to check before installing, including airflow, outlet, and unpacking procedures.

Top Rail Installation

Instructions for attaching the top mounting rail to the air conditioner case.

Curtain Installation

Steps for installing the side curtains and securing them to the window frame.

Placing Unit in Window

Detailed steps for positioning the air conditioner within a standard window frame.

Weather Insulation Board Installation

Procedure for installing the insulation board to improve sealing and efficiency.

Removal from Window (End of Season)

Instructions for safely removing the unit from the window at the end of the cooling season.

Control Panel Overview

Control Panel Features

Description of buttons, display, and indicators on the air conditioner's control panel.

Timer Functions

Explanation of how to set and use the auto-on and auto-off timer features.

Remote Control

Remote Control LCD Display

Explanation of the icons and information shown on the remote control's LCD screen.

Operation Instructions

Remote Control Operations

Detailed instructions for using the remote control to operate the air conditioner modes and functions.

Using the Air Conditioner

Freezing Conditions Warning

Important warning against operating the air conditioner in freezing outdoor conditions.

Cooling Mode Operation

Guidance on using the Cooling mode with different fan speeds and temperature settings.

Energy Saver Mode

Explanation of the Energy Saver mode and its impact on temperature and humidity.

Fan Only Mode

How to use the Fan Only mode for air circulation without cooling.

Loss of Power Protection

Details on how the unit restarts after a power interruption and timer cancellation.

Air Direction

How to adjust the airflow direction using the levers on the front air vents.

Auto Mode

Explanation of the Auto mode's function to automatically select cooling or fan.

Ventilation Control

Instructions for operating the fresh air vent lever for ventilation.

Use and Care

Air Filter Cleaning

Instructions for cleaning the air filter to maintain airflow and prevent frost buildup.

Wear and Tear

Guidance on minimizing wear and tear by waiting before changing modes.

Cabinet Cleaning

Instructions for cleaning the air conditioner cabinet safely and effectively.

Winter Storage

Procedure for storing the air conditioner properly during the off-season.

Error Codes

List of error codes and their meanings for troubleshooting.

Troubleshooting

Air Conditioner Will Not Start

Common causes and solutions for the air conditioner failing to power on.

Air Conditioner Does Not Cool

Troubleshooting steps for when the air conditioner is not cooling effectively.

Air Conditioner Freezing Up

Causes and solutions for ice buildup on the cooling coils.

Water is Dripping Outside

Explanation for water dripping from the unit during hot and humid weather.

Water Dripping Inside the Room

Troubleshooting for water leaks inside the room due to improper tilting.

Water Collects in the Base Pan

Reasons for water accumulation in the base pan, especially in low humidity.

Remote Control Not Working

Solutions for a non-functional remote control, including battery checks.

Limited Warranty

Overview

This document describes the Soleus Air Window Air Conditioner, a cooling appliance designed for indoor use.

Function Description

The Soleus Air Window Air Conditioner is designed to provide cooling, dehumidification, and air circulation within a room. It features multiple operating modes including Cool, Dry (Dehumidifier), Fan, Auto, Sleep, and Energy Saver. The unit is equipped with an electronic control panel and a remote control for convenient operation.

Cooling Mode: This mode allows the user to set a desired temperature between 61°F and 90°F. The compressor cycles on and off to maintain the set temperature, with adjustable fan speeds (High, Medium, Low). Dry Mode (Dehumidifier): This mode helps reduce humidity in the room. Fan Only Mode: Provides air circulation and filtering without cooling, with adjustable fan speeds (High, Medium, Low). A set temperature cannot be entered in this mode. Auto Mode: The air conditioner automatically selects between Cool or Fan mode based on the current room temperature. Sleep Mode: Available in Cool, Dry, Auto, and Fan modes. The fan runs on low speed, and the temperature setting gradually increases by 2°F over the first two hours to maintain comfort while minimizing noise. Energy Saver Mode: When activated (default ON), the fan cycles on and off with the compressor to limit energy consumption. This mode is only available in COOL mode and is recommended for unoccupied rooms or when a wider temperature range is acceptable. If OFF, the fan runs continuously in fan or cool mode.

Timer Function: Allows users to set an Auto-on or Auto-off timer for 1-24 hours. The Auto-on timer activates the unit at previous settings, while the Auto-off timer turns it off after a set duration. MYTEMP Mode: Changes the thermostat sensor from the air conditioner to the remote control's location, allowing the unit to cool the area based on the remote's position and set temperature. Child Lock: Locks/unlocks the remote control buttons. Loss of Power Protection: The unit automatically restarts with the last used settings after a power interruption, though the timer function will be cancelled. Air Direction: Adjustable levers on the front air vents allow users to direct airflow (left, right, up, or down). Ventilation: A Fresh Air Lever (unavailable on WS1-06E-02 model) can be pushed to close the vent for optimal cooling or pulled to open it for fresh air recirculation.

Important Technical Specifications

The Soleus Air Window Air Conditioner models vary in cooling capacity and dimensions:

  • WS1-06E-02:

    • Rated Cooling Capacity: 6,200 BTU/h
    • Cooling Power Input: 495 Watts
    • Rated Current Cooling: 4.3 Amperage
    • CEER: 12.1
    • Dehumidifying Capacity: 30.48 Pints per day
    • Product Dimensions (W x H x D): 18.625" x 12.625" x 15.5"
    • Net/Gross Weight: 46.3/55.1 Lbs
    • Refrigerant Type: R-410A
    • Plug Type: NEMA 5-15P
    • Min. Window Opening: 13 1/4"
    • Min. Window Width: 22 1/4"
    • Max Window Width: 38"
  • WS1-08E-02:

    • Rated Cooling Capacity: 8,000 BTU/h
    • Cooling Power Input: 667 Watts
    • Rated Current Cooling: 6.5 Amperage
    • CEER: 12
    • Dehumidifying Capacity: 34.8 Pints per day
    • Product Dimensions (W x H x D): 19" x 14.375" x 19.5"
    • Net/Gross Weight: 57.3/63.9 Lbs
    • Refrigerant Type: R-410A
    • Plug Type: NEMA 5-15P
    • Min. Window Opening: 14 3/4"
    • Min. Window Width: 22 1/2"
    • Max Window Width: 36 7/8"
  • WS1-10E-02:

    • Rated Cooling Capacity: 10,200 BTU/h
    • Cooling Power Input: 850 Watts
    • Rated Current Cooling: 7.5 Amperage
    • CEER: 12
    • Dehumidifying Capacity: 43.4 Pints per day
    • Product Dimensions (W x H x D): 19" x 14.375" x 21.5"
    • Net/Gross Weight: 66/72 Lbs
    • Refrigerant Type: R-410A
    • Plug Type: NEMA 5-15P
    • Min. Window Opening: 14 3/4"
    • Min. Window Width: 22 1/2"
    • Max Window Width: 36 7/8"
  • WS1-12E2-02:

    • Rated Cooling Capacity: 12,000 BTU/h
    • Cooling Power Input: 1,000 Watts
    • Rated Current Cooling: 8.7 Amperage
    • CEER: 12
    • Dehumidifying Capacity: 52.3 Pints per day
    • Product Dimensions (W x H x D): 19" x 14.375" x 21.5"
    • Net/Gross Weight: 72.7/77.2 Lbs
    • Refrigerant Type: R-410A
    • Plug Type: NEMA 5-15P
    • Min. Window Opening: 14 3/4"
    • Min. Window Width: 22 1/2"
    • Max Window Width: 36 7/8"

All models operate on a 1/115/60 power supply. Noise levels (L/H) range from 55/58 dB(A) to 58/61 dB(A) depending on the model.

Power Cord and Plug: The unit is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug, which disconnects power if current leakage is detected. Test and Reset buttons are provided on the plug to ensure proper functioning. It is crucial not to use extension cords or adapter plugs, and never remove the ground prong. The unit must be upright for 24 hours prior to operating to ensure compressor function.

Usage Features

Installation: Designed for standard double-hung windows. Two people are recommended for installation due to the unit's size. Special considerations are provided for storm windows to ensure proper drainage. The unit should be tilted slightly to the outside for condensation drainage. Weather Insulation Boards are included to prevent air leakage. Remote Control: The remote control has a signal range of up to 20 feet. It requires two AAA batteries (not included), and it's advised not to mix old and new batteries or different types. Normal Operating Sounds: Users may hear a "pinging" noise from water hitting the condenser, a "clicking" sound from the thermostat, and water collecting in the base pan during high humidity, which may drip outside. These are considered normal operational sounds. Error Codes: The digital display shows error codes for troubleshooting: E2 for room temperature sensor failure and E3 for room temperature pipe sensor failure. If these persist after power cycling, customer service should be contacted.

Maintenance Features

Air Filter Cleaning: The air filter should be checked and cleaned at least once a month. It can be removed, washed with liquid dish soap and warm water, rinsed, and air-dried, or vacuumed to remove dust. A "Filter Reset" button on the control panel reminds the user to clean the filter after 250 hours of fan operation. Cabinet Cleaning: The cabinet and front panel can be dusted with an oil-free cloth or washed with a damp cloth and mild liquid soap. Harsh cleaners, wax, or polish should not be used. Ensure excess water is wrung from cloths when cleaning around controls to prevent damage. Winter Storage: For extended non-use, the unit should be carefully removed from the window, covered with plastic, or placed in its original box. Wear and Tear: To minimize wear and tear and extend product life, it is recommended to wait at least 3 minutes before changing operating modes.

Safety Warnings: This product may expose users to chemicals like Lead and Bisphenol-A, known to cause birth defects or reproductive harm (as per California's Proposition 65). Users are advised to visit www.P65Warnings.ca.gov for more information. It is crucial to follow all safety messages, especially regarding electrical safety, to prevent fire, electrical shock, or injury. The unit is a cooling-only air conditioner and should not be used in freezing outdoor conditions.

Soleus Air WS1-06E-02 Specifications

General IconGeneral
BrandSoleus Air
ModelWS1-06E-02
CategoryAir Conditioner
LanguageEnglish