ENGLISH 13
13.5 Spark Plug
The correct spark plug with thermal range 145 is
available under the following brands:
BOSCH W8AC
Champion RL86C
The correct electrode gap is 0.5mm.
Caution: Check the plug after every 50
operating hours and replace if electrodes
are worn.
13.6 Storage Hints
If the unit is to be laid up or kept idle for any length
of time, proceed as follows:
a) Rinse and clean thoroughly. Never use formula
container of your mist blower for storing
chemicals.
b) Shut off fuel cock and keep engine running
until lines and carburetor are empty. Otherwise
gasoline evaporates, and the remaining
lubricant would clog the carburetor ducts.
c) Remove spark plug and squirt an ounce or two
of corrosion inhibitor (LPS, WD-40 etc.) or
plain engine oil into the cylinder. Crank engine
several times to spread the agent, and then
reinsert spark plug.
d) Please store your machine away from sunlight,
order to protect of the materials against
influence of ultraviolet radiations.
e) Before putting the unit back into service,
remove and clean spark plug; crank engine a
few times with plug removed.
For transport in a vehicle, ensure the
mistblower is well secured to avoid fuel
spillage.
Completely empty the fuel tank before extended
storage or shipment.
14. Draining and cleaning the tank
For cleaning purposes, the tank can be fully
drained into a suitable container via the supply
hose.
For this, the engine must be cooled down.
Position the equipment onto a stable higher
support, so that the spray medium can drain into a
suitable container below.
Above the container, pull the supply hose from the
shut-off valve.
If required, tip the equipment slightly to drain the
tank completely.
Ensure that the spray medium does not run over
the equipment (especially the engine), but drains
directly into the suitable container.
Dispose of residual spray medium correctly at
disposal sites licensed for specialised waste.
Empty the spray medium tank daily after work and
flush thoroughly with water.
Observe cleaning instructions supplied with the
herbicide/fungicide.
Occasionally clean the strainer inside the filler
neck, the strainer in the accessory set and all parts
in contact with the medium, with water and a soft
brush.
After cleaning, let the spray medium container dry
in an open state.
Fig. 20
Fig. 21