Radio receiver for rolling garage door
Installation Manual
Power supply voltage : 230Vac 50-60 Hz.
Fuse : 250V 5A with timeout
Max motor power : 230Vac 750W.
Protection rating : IP 55.
Ambient operating T° : -15°C to +55°C.
Radio frequency : 433.42MHz
Accessory power supply : 24Vcc (direct).
Resistance values for resistive sensor
bar : From 4 to 12K
Maximum current for accessories : 0.33A i.e. 8W max.
(cells, keypads, loops, sensor bar, etc…) or 13W intermittent (orange light
10W + accessories 3W.)
Orange light : 24V, 10W max or 230V 40W max
Area lighting : 230Vac, 500W.
Auxiliary output : Contact NO, 250Vac 500W.
Operating class : 1, the ground must be connected.
Number of maximum channels : 32
150 mm
150 mm
40 mm
=
: Automatic mode
Pressing the remote control opens and closes automatically
after timeout T1 (chapter 3.8).
During closing, pressing the remote control again or the
detection of an obstacle reopens the door.
=
: Semi-automatic mode
Pressing the control triggers opening or closing. Pressing again
during opening has no effect.
Pressing during closing reopens the door.
=
: Sequence mode (default mode)
Cyclic operation (up / stop / down / stop...).
Pressing during opening or closing stops
without reversion.
=
: Sequential mode + Timeout
Similar to the sequential mode, but with automatic closing
after timeout T1 (chapter 3.8).
=
: 3-button mode
This mode is used to set a separate control
for opening, closing, and stopping the
door.
=
: Forced mode with + & - keys on
the keyboard
This mode is used to control the door using the “ + ” and
- ” keys on the Axroll box in the endstop adjustment phase.
Press and hold “
+ ” to open.
Press and hold “ - ” to close.
GB
3.1 Con
figuring the operating mode: parameter (PLANT VALUE = 02)
The AXROLL receiver is used to control a rolling garage door fitted with
a 230V motor with mechanical built-in endstops using Keytis
NS
2/4 RTS,
Telis 1/4 RTS, and radio wall switch.
Different safety and signaling systems can be connected to the
AXROLL
(resistive, OSE Fraba type or ultrasonic safety edge, photocells, flashlights,
area lighting).
Hereby, SOMFY, declares that this product (AXROLL) is in compliance with the
essential requirements and other relevant provisions of Directive 1999/5/EC.
A Declaration of Conformity is available at the web address www.somfy.com/CE.
Usable in EU,
Ref. N1841034E V1
SOMFY SAS, capital 20 000 000 Euros, RCS Bonneville 303 970 230
in this mode, the safety devices are deactivated
Mandatory installation of safety accessories
Mandatory installation of safety accessories
lighting or
signaling
chapter 3.7
Keyswitch
Radio
Wall
Switch
sensor bar
photocells
MAINS
230V - 50Hz
Certain operating modes impose connecting safety accessories (european standards EN 12453). Non compliance with these rules can lead to a facility
h
azardous for its users.
The Axroll has six operating modes:
Configuration
Use the “ + “ or - “ keys to change the value of the
parameter.
The last value is recorded automatically (the display is
fixed when pressing the keys).
1 sec.
Use the “ “ or “ keyrs to
browse the menu and display
the parameter required.
One second after releasing the key,
the screen indicates the parameter
value to change.
(display blinks)
The Axroll control box is fully and easily configured to achieve optimum operation matching the types of accessories connected, as
well as the operation mode required by the user.
The various parameters proposed are not mandatory, and browsing the menus imposes no particular sequence.
Powering on the product: the display indicates the value
Check the motor’s rotation direction using the “
+ “ and “ - “ keys.
press and hold the “
+ “ key to open the door.
press and hold down the “ - “ key to close the door.
If the operation is reversed, power off the product, and revert the motor’s wiring
(terminals 7 and 9).
Refer to the motor's installation manual to set the end stop system.
CH
Axroll
NS
12 12345
24V
ac/dc
24V
ac/dc
0V 0V C NC NO
Ground
Phase
Neutral
Motor
Safety
Break
White
(pin -)
Brown
(pin +)
Green
(pin SEC)
OSE SAFETY EDGE
(FRABA)
(
cf. P5 parameter)
Photocells. Ref: 9012763
Keyswitch
Sensor
bar
Ampli
Test
Supply
Contact
230V - 50Hz
Lighting configuration
Ground
Phase
Neutral
lighting
500W max.
Orange light configuration
orange lights.
switch off the mains before any
intervention.
use flexible cables.
connect the ground cables.
after installation, no traction must be
applied to the terminal strips.
Apply the electric installation stan-
dards, as well as the following points:
3
Wiring
1
Checking the motor’s rotation direction
2
Motor ( +safety break)
Measure the motor operating time using permanent running (e.g. 20sec. for rising), then set the T0 parameter (motor operating time,
chapter 3.8) with a value slightly above the time observed (about +3 sec.).
This product complies with the standard EN 60335-2-95.
When installed as recommended in this instruction manual and in accordance with regulations in
force, Axroll allows the installation to comply with EN 13241 and EN 12453 standards. Axroll must
be installed inside the garage with a motor equipped by a manual override system.
To return to the menu, press the “
“ or
“ keys to return to value C1 (or any other value indicating the pro-
duct’s operation: see § 4) or after a one-minute waiting time.
1
2
3
Pull the antenna wire
through the right-hand
wire grommet.
cf. PA parameter
or
NB: If you want to check the motor's rotation direction, you have to set the parameter
=
(chapter 3.1)

Other manuals for SOMFY Axroll

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SOMFY Axroll and is the answer not in the manual?

SOMFY Axroll Specifications

General IconGeneral
BrandSOMFY
ModelAxroll
CategoryReceiver
LanguageEnglish

Related product manuals