4.4 Setting the run time (run time monitoring)
When DIP switch 8 is “OFF”, motor run time monitoring is deacti-
vated. Previously programmed run times are deleted and must be
reprogrammed. This is the case if a relay clicks audibly when the
door is not moving.
1. Set DIP switch 8 to “ON”.
2. Open and close the door to the end positions.
Relay stops clicking when the motor is not running. Otherwise
repeat the step.
The run times in both directions are now programmed.
3. Leave DIP switch 8 “ON”. This means that the run times will be
monitored constantly and the control unit stops the operator if they
are exceeded.
4.5 Wiping the radio receiver’s memory
For security reasons, you should completely wipe the radio receiver’s
memory:
• before programming transmitters for the first time and
• if a transmitter is lost.