EasyManua.ls Logo

Sonitrol iCLASS - Access Control Keypad Operation; Using Your Sonitrol System; Arming Your Security System

Sonitrol iCLASS
14 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
19810016 REV C Standard and iCLASS Enhanced Keypad
Page 3
Occupied Security: This allows predefined areas of your premises to be protected (i.e.
exterior doors, windows, etc.) while the interior of the building remains occupied. There are
two levels of occupied security available:
Instant: Sends an alarm immediately to the monitoring console if predefined areas of
your premise are violated.
Delay: Entry/Exit delay allows for authorized persons to leave or enter through
designated doors before sending an alarm to the monitoring console. All other exterior
protection will generate immediate alarms when violated.
Disarmed: Selected to disarm your security system and only monitor devices such as Hold-
up, Temperature Control, etc.
1.5 Access Control Keypad
The LED status on the keypad will be red when the door is locked, green when the door is unlocked,
and amber when either a card is swiped that does not exist in the system or the user does not have
authority.
Note: Keypads used as Arm/Disarm keypads are unable to access system menus.
Note: Keypads used as Arm/Disarm keypads can only be used as entry keypads and not exit.
1. For access through a door using a keypad for access, the user should either enter their access
code and press ENTER or swipe their card. Upon verification, the door can be opened.
2. If 911 is enabled, the user can press 911 and then press ENTER if an emergency occurs.
3. If a duress code is enabled, the user can press the ARM/DISARM button enter the duress code
and press ENTER to alert the Monitoring Center of duress while changing the state of the
partition from ARMED to DISARMED or from DISARMED to DISARMED. If the duress code is
entered without pressing the ARM/DISARM button, the Monitoring Center will receive the duress
alarm and the partition state will remain the same.
2. Using Your System
2.1 Arming Your System
1. Press the ARM/DISARM Button.
2. When prompted present Card/Key fob or enter access code and press ENTER.
Note: Your Access Code should be 1-8 digits.
Note: If there is only one partition, skip to step 5.
3. Select the partition you want to arm:
THIS PARTITION: arms the local partition
MY PARTITIONS: arms only the partitions your Access Code is programmed to control
4. Press ENTER.
The keypad briefly displays: PLEASE WAIT WHILE ARMING...
5. When the keypad displays: ARMED XXX SEC TO EXIT. The Keypad sounder will begin beeping,
exit the door or building and verify the door is closed and locked.
Note: The keypad will display Armed when in the Armed State.
Loss of communications, over IP or Telephone, will NOT allow the system to Arm.