SECTION
2
ADJUSTMENTS
ELECTRICAL
ADJUSTMENTS
1.
Perform
adjustments
in
the
order
given.
2.
Use
YEDS-18
(Part
No.
3-702-101-01)
disc
unless
otherwise
indicated.
3.
Use
the
oscilloscope
with
more
than
10M{Q2
im-
pedance.
RF
PLL
Frequency
Adjustment/Lock
Frequency
Check
Procedure:
frequency
counter
main
board
ara.
TP
(PCK)
0-——-—_O
TP
(GND)
o——+o
.
Ground
test
point
TP
(ASY).
.
Connect
the
frequency
counter
to
the
test
points
TP
(PCK)
and
TP
(GND).
.
Turn
POWER
switch
on.
.
Adjust
RV205
so
that
the
reading
on
the
fre-
queny
counter
is
4.3218
MHz.
..
(RF
PLL
frequency
adjustment)
5.
Remove
the
grounding
wire
from
TP
(ASY).
6.
Put
the
disc
(YEDS-18)
in
and
press
p
button.
.
Confirm
that
the
reading
on
the
frequency
counter
is
locked
at
4.3218
MHz.
E-F
Balance
Adjustment
This
adjustment
should
be
made
after
replacing
the
Optical
Pick-up
Block.
Procedure:
oscilloscope
(DC
range)
main
board
C)
TP
(TEO)
O0-——-——__O+
TP
(A
GND)
O—_——__,0
-
Focus
Bias
Adjustment
This
adjustment
should
be
made
after
replacing
the
Optical
Pick-up
Block.
Procedure:
oscilloscope
(DC
range)
main
board
TP
(RF)
=a
TP
(RFG)
o_O
--
1.
Connect
oscilloscope
to
the
test
points
TP
(RF)
and
TP
(RFG).
2.
Turn
POWER
switch
on.
3.
Put
the
disc
(YEDS-18)
in
and
press
>
button.
4,
Adjust
RV202
for
an
optimum
waveform
eye
pat-
tern.
Optimum
eye
pattern
means
that
shape
“©”
can
be
clearly
distinguished
at
the
center
of
the
-waveform.
XXX
WY
Wy
(x)
7.1-—1.5
Vp-p
AWAY
ONY
~0.1—0.05V
_
1.
Connect
the
oscilloscope
to
the
test
points
TP
(TEO)
and
TP
(A
GND).
.
Ground
TP
(ADJ)
to
set
an
adjustment
mode.
.
Turn
POWER
switch
on.
.
Put
the
disc
(YEDS-18)
in
and
press
p>
button,
nA
F&F
W
bv
.
Adjust
RV201
so
that
the
traverse
waveform
is
symmetrical
above
and
below.
6.
After
adjustment,
cancel
the
adjustment
mode.
VOLT/DIV:
1V
TIME/DIV:
1ms