EasyManua.ls Logo

Sony DVP-S725D - Adjustment of Video System; Video Level Adjustment; S-Terminal Output Check; Checking Component Video Output B-Y

Sony DVP-S725D
134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
7-2
7-2. ADJUSTMENT OF VIDEO SYSTEM
1. Video Level Adjustment (MB-82/85 BOARD)
<Purpose>
This adjustment is made to satisfy the NTSC standard, and if not
adjusted correctly, the brightness will be too large or small.
Mode Video level adjustment in test mode
Signal Color bars
Test point
LINE OUT (VIDEO) connector
(75 terminated)
Instrument Oscilloscope
Adjusting element RV401
Specification 1.0 ± 0.02 Vp-p
Adjusting method:
1) In the test mode initial menu “6” Video Level Adjustment, set
so that color bars are generated.
2) Adjust the RV401 to attain 1.0 ± 0.02 Vp-p.
Figure 7-1
2. S-terminal Output Check (MB-82/85 BOARD)
<Purpose>
Check S-terminal video output. If it is incorrect, pictures will not
be displayed correctly in spite of connection to the TV with a S-
terminal cable.
Mode Video level adjustment in test mode
Signal Color bars
Test point
S VIDEO OUT (S-Y) connector
(75 terminated)
Instrument Oscilloscope
Specification 1.0 ± 0.1 Vp-p
Checking method:
1) In the test mode initial menu “6” Video Level Adjustment, set
so that color bars are generated.
2) Confirm that the S-Y level is 1.0 ± 0.1 Vp-p.
Figure 7-2
3. Checking Component Video Output B-Y
(MB-82/85 BOARD) (DVP-S525D: Australian/S725D)
<Purpose>
This checks component video output B-Y. If it is incorrect, cor-
rect colors will not be displayed when connected to, for instance,
projector.
Mode Video level adjustment in test mode
Signal Color bars
Test point
COMPONENT VIDEO OUT (B-Y)
connector (75 terminated)
Instrument Oscilloscope
Specification 700 ± 70 mVp-p
Checking method:
1) Confirm that the B-Y level is 700 ± 70 mVp-p.
Figure 7-3
4. Checking Component Video Output R-Y
(MB-82/85 BOARD) (DVP-S525D: Australian/S725D)
<Purpose>
This checks component video output R-Y. If it is incorrect, cor-
rect colors will not be displayed when connected to, for instance,
projector.
Mode Video level adjustment in test mode
Signal Color bars
Test point
COMPONENT VIDEO OUT (R-Y)
connector (75 terminated)
Instrument Oscilloscope
Specification 700 ± 70 mVp-p
Checking method:
1) Confirm that the R-Y level is 700 ± 70 mVp-p.
Figure 7-4
700 ± 70 mVp-p
1.0 ± 0.02 Vp-p
1.0 ± 0.1 Vp-p
700 ± 70 mVp-p

Table of Contents

Other manuals for Sony DVP-S725D

Related product manuals