Command List
FCB-EH6500(GB) A-EEP-100-11(1)
35
VISCA Camera-Issued Messages
Acknowledge/Completion Messages
Command Messages Comments
Acknowledge z0 4y FF
(y:Socket No.)
Returned when the command is accepted.
Completion z0 5y FF
(y:Socket No.)
Returned when the command has been executed.
z = Device address + 8
Error Messages
Command Messages Comments
Syntax Error z0 60 02 FF Returned when the command format is different or when a command with illegal
command parameters is accepted.
Command Buffer Full z0 60 03 FF Indicates that two sockets are already being used (executing two commands) and the
command could not be accepted when received.
Command Canceled z0 6y 04 FF
(y:Socket No.)
Returned when a command which is being executed in a socket specified by the cancel
command is canceled. The completion message for the command is not returned.
No Socket z0 6y 05 FF
(y:Socket No.)
Returned when no command is executed in a socket specified by the cancel command,
or when an invalid socket number is specified.
Command Not Executable z0 6y 41 FF
(y:Socket No.)
Returned when a command cannot be executed due to current conditions. For example,
when commands controlling the focus manually are received during auto focus.
Network Change Message
Command Message Comments
Network Change z0 38 FF Issued when power is being routed.