HCD-EC68P/EC78P
5
CAPACITOR DISCHARGE FOR ELECTRIC SHOCK PREVENTION
MAIN board
MAIN board
C626
C622
In checking the MAIN board, make a capacitor discharge
of C622 and C626 for electric shock prevention.
800 Ω/2W
800 Ω/2W
Model Power Voltage Indication
EC68P: US/EC78P:
US and Canadian models
AC 120 V, 60 Hz
EC68P: Australian model
AC 230 - 240 V, 50/60 Hz
EC78P: UK model AC 230 V, 50/60 Hz
MODEL IDENTIFICATION
– Back Panel –
POWER
VOLTAGE
INDICATIO