6-48
HVR-M25J/M25U/M25N/M25E/M25P/M25C
2-5. Processing after Complete Adjustment
Perform the setting through the procedure mentioned below when
you finish the “S VIDEO, VIDEO OUT Adjustment”.
Order Page Address Data Procedure
10 1001
2
C
0F 00 Press PAUSE (Write) button.
(1C)
3
8
04 80 Press PAUSE (Write) button.
(18)
4
8
00 00 Press PAUSE (Write) button.
(18)
5
8
01 00 Press PAUSE (Write) button.
(18)
6
8
06 00 Press PAUSE (Write) button.
(18)
70 1000
80 0100
2-4. VIDEO OUT Level Check (VD-036 board)
Mode E-E
Signal No signal
Measurement Point VIDEO OUT jack (75 terminated)
Measuring Instrument Oscilloscope
Specified value Sync level: A = 286 ± 18 mVp-p(NTSC)
A = 300 ± 18 mVp-p(PAL)
Burst level: B = 286 ± 18 mVp-p(NTSC)
B = 300 ± 18 mVp-p(PAL)
Checking method:
Order Page Address Data Procedure
1 Perform “Preparations”.
2
Set the HOLD switch of
adjustment remote com-
mander to “OFF” (NORMAL
position).
3
Set the 60i/50i SEL (OTH-
ERS menu) to “60i”.
4
Check the sync signal level
(A) to the NTSC specified
value.
5
Check the burst signal level
(B) to the NTSC specified
value.
6
Set the 60i/50i SEL (OTH-
ERS menu) to “50i”.
7
Check the sync signal level
(A) to the PAL specified
value.
8
Check the burst signal level
(B) to the PAL specified
value.
9
Set the HOLD switch of
adjustment remote com-
mander to “HOLD” (SER-
VICE position).
10
Perform “Processing after
Complete Adjustment”.
Fig. 6-2-5