6-51
HVR-M25J/M25U/M25N/M25E/M25P/M25C
H
A
4-4.COMPONENT OUT Pr Level Adjustment
(D1 SMPTE) (VD-036 board)
Mode E-E
Signal No Signal
Measurement Point Pr/Cr terminal of COMPONENT
OUT jack (75 terminated)
Measuring Instrument Oscilloscope
Adjustment Page C
Adjustment Address 95
Specified value Pr level: A = 525 ± 10 mVp-p
Fig. 6-2-9
4-5. Processing after Complete Adjustment
Perform the setting through the procedure mentioned below when
you finish the “COMPONENT OUT Adjustment (D1 SMPTE)”.
Order Page Address Data Procedure
18 00
Set the bit value of bit1 is
“0”, and press PAUSE
button. (Note)
20 1001
300
Set the bit value of bit7 is
“0”, and press PAUSE
button. (Note)
4CF
Set the bit value of bit0 is
“0”, and press PAUSE
button. (Note)
50 1000
60 0100
Adjusting method:
Order Page Address Data Procedure
1 Perform “Preparations”.
2C 95
Change the data and set the
Pr signal level (A) to the
specified value.
3C 95 Press PAUSE (Write) button.
4
Perform “Processing after
Complete Adjustment”.
Note: For the bit values, refer to “6-3. SERVICE MODE”, “3-
4. 4. Bit value discrimination”.
3
(13)
8
(18)