6-50
HVR-M25J/M25U/M25N/M25E/M25P/M25C
4-2.COMPONENT OUT Y Level Adjustment
(D1 SMPTE) (VD-036 board)
Mode E-E
Signal No Signal
Measurement Point Y terminal of COMPONENT OUT
jack (75 terminated)
Measuring Instrument Oscilloscope
Adjustment Page C
Adjustment Address 93
Specified value Y level: A = 1000 ± 10 mVp-p
Sync level: B = 300 ± 10 mVp-p
Adjusting method:
Order Page Address Data Procedure
1 Perform “Preparations”.
2C 93
Change the data and set the Y
signal level (A) to the
specified value.
3C 93 Press PAUSE (Write) button.
4
Check the sync signal level
(B) to the specified value.
5
Perform “Processing after
Complete Adjustment”.
H
A
B
Fig. 6-2-7
4-3.COMPONENT OUT Pb Level Adjustment
(D1 SMPTE) (VD-036 board)
Mode E-E
Signal No Signal
Measurement Point Pb/Cb terminal of COMPONENT
OUT jack (75 terminated)
Measuring Instrument Oscilloscope
Adjustment Page C
Adjustment Address 94
Specified value Pb level: A = 525 ± 10 mVp-p
Adjusting method:
Order Page Address Data Procedure
1 Perform “Preparations”.
2C 94
Change the data and set the
Pb signal level (A) to the
specified value.
3C 94 Press PAUSE (Write) button.
4
Perform “Processing after
Complete Adjustment”.
H
A
Fig. 6-2-8