6-53
HVR-M25J/M25U/M25N/M25E/M25P/M25C
H
A
H
A
Fig. 6-2-11
Fig. 6-2-12
5-4. COMPONENT OUT Pr Level Adjustment
(D1 BETACAM) (VD-036 board)
Mode E-E
Signal No Signal
Measurement Point Pr/Cr terminal of COMPONENT
OUT jack (75 terminated)
Measuring Instrument Oscilloscope
Adjustment Page C
Adjustment Address 9B
Specified value Pr level: A = 756 ± 10 mVp-p
Adjusting method:
Order Page Address Data Procedure
1 Perform “Preparations”.
2
Set the HOLD switch of
adjustment remote com-
mander to “OFF” (NORMAL
position).
3 Set the 60i/50i SEL (OTH-
ERS menu) to “60i”.
4
Set the HOLD switch of
adjustment remote com-
mander to “HOLD” (SER-
VICE position).
5C 9B
Change the data and set the
Pr signal level (A) to the
specified value.
6C 9B Press PAUSE (Write) button.
7
Set the HOLD switch of
adjustment remote com-
mander to “OFF” (NORMAL
position).
8
Set the 60i/50i SEL (OTH-
ERS menu) to “50i”.
9
Check the Pr signal level (A)
to the specified value.
10
Set the HOLD switch of
adjustment remote com-
mander to “HOLD” (SER-
VICE position).
11
Perform “Processing after
Complete Adjustment”.
5-3. COMPONENT OUT Pb Level Adjustment
(D1 BETACAM) (VD-036 board)
Mode E-E
Signal No Signal
Measurement Point Pb/Cb terminal of COMPONENT
OUT jack (75 terminated)
Measuring Instrument Oscilloscope
Adjustment Page C
Adjustment Address 9A
Specified value Pb level: A = 756 ± 10 mVp-p
Adjusting method:
Order Page Address Data Procedure
1 Perform “Preparations”.
2
Set the HOLD switch of
adjustment remote com-
mander to “OFF” (NORMAL
position).
3
Set the 60i/50i SEL (OTH-
ERS menu) to “60i”.
4
Set the HOLD switch of
adjustment remote com-
mander to “HOLD” (SER-
VICE position).
5C 9A
Change the data and set the
Pb signal level (A) to the
specified value.
6C 9A Press PAUSE (Write) button.
7
Set the HOLD switch of
adjustment remote com-
mander to “OFF” (NORMAL
position).
8
Set the 60i/50i SEL (OTH-
ERS menu) to “50i”.
9
Check the Pb signal level (A)
to the specified value.
10
Set the HOLD switch of
adjustment remote com-
mander to “HOLD” (SER-
VICE position).
11
Perform “Processing after
Complete Adjustment”.