KE-42TS2E(AEP/UK) 2-2
9. Repeat step 6 to 8 until the detection set value in step 6 above is ob-
tained.
10. Repeat step 1 and 4 to 9 until the detection set value in steps 4 and 6
above are obtained.
2-1-4. Video input adjustment
1. Input All white 90 IRE signal of NTSC to the video input terminal.
2. Set Picture Mode into “Personal2”.
(Caution) The order of 1, 2 must not be changed.
3. Select Video Calibration from the AD Converter menu.
4. Adjust the Sub Contrast (Video) and then, adjust the detection values of
G to the set value.
Detection set value: 230 ± 3
5. Set the video input signal to All gray 20 IRE signal of NTSC.
6. Adjust the Sub Bright (Video) and then, adjust the detection values of
G to the set value.
Detection set value: 51 ± 3
7. Adjust the CB Offset (Video) and then, adjust so that the detection
value of B is the same as G value.
7. Repeat step 1 and 3 to 6 described above until the detection set value is
obtained.
2-1-3. Component input adjustment
1. Input All white 90 IRE signal of 1080/60i to the component input ter-
minal.
2. Set Picture Mode into “Personal2”.
(Caution) The order of 1, 2 must not be changed.
3. Select YUV Calibration from the AD Converter menu.
4. Adjust the Sub Contrast (YUV) and then, adjust the detection values of
G to the set value.
Detection set value: 230 ± 3
5. Set the component input signal to All gray 20 IRE signal of 1080/60i .
6. Adjust the Sub Bright (YUV) and then, adjust the detection values of G
to the set value.
Detection set value: 51 ± 3
7. Adjust the CB Offset (YUV) and then, adjust so that the detection value
of B is the same as G value.
8. Adjust the CR Offset (YUV) and then, adjust so that the detection value
of R is the same as G value.