Appendix
Appendix A-25
CURRENT TRACK REMAIN TIME
RETURN
Command: 0DCH
Function: Returns information for the “CURRENT
TRACK REMAIN TIME SENSE”: 05CH.
DATA: 2
DATA1 (minute)
DATA2 (second)
REQUEST command: 05CH
TOTAL TRACK No., TOTAL TIME
RETURN
Command: 0DDH
Function : Returns information for the “TOTAL
TRACK No., TOTAL TIME SENSE”: 05DH.
DATA: 4
DATA1 (10, 1) TOTAL TRACK No.
DATA2 (**, 100) TOTAL TRACK No.
DATA3 (minute) TOTAL TIME
DATA4 (second) TOTAL TIME
REQUEST command: 05DH
HOUR METER RETURN
Command: 0DEH
Function: Returns information for the “HOUR
METER SENSE”: 05EH.
DATA: 4
DATA1
000H: Total operation hours of spindle motor
002H: Total operation hours of optical pick-
up (in RECORD mode)
DATA2 (10, 1)
DATA3 (1000, 100)
DATA4 (**, 10000)
REQUEST command: 05EH
ERROR SENSE RETURN
Command: 0F8H
Function : Returns information for the “ERROR
SENSE” : 078H.
DATA: 2
DATA1 (**, ***)
DATA2 ( , *)
Note
Read the above case as *-**,*** (Example: 1-
05, 2-50).
In case of no error:
DATA1 (0, 0)
DATA2 ( , 0)
REQUEST command: 078H
ERROR code:
1-04: An error occurred in RAM (Random
Access Memory: write/read memory).
CAUTION SENSE RETURN
Command: 0F9H
Function : Returns information for the “CAUTION
SENSE”: 079H.
DATA: 2
DATA1 (**, ***)
DATA2 ( , *)
Note
Read the above case as *-** ***.
In case of no caution:
DATA1 (0, 0)
DATA2 ( , 0)
REQUEST command: 079H
ERROR code:
1-05: Backup Data Clear
1-11: Digital IN Unlock
1-13: Protected (disc is record-protected)
1-14: Disc Full (no area remains for recording)
1-16: Retry (recording is retried because of
vibration and flaw in disc)
1-17: Disc Error (many flaws or no TOC in
disc)
1-18: Cannot Edit (editing is impossible)
1-19: Impossible or Sorry (editing is
impossible)