36
Data: 01H, Status
Status: 02H=On
03H=Off
Details of function:Indicates Power status.
MDS outputs this data when it receives “POWER” and the status
changes.
Also, MDS outputs “STATUS DATA” when the status of Power changes.
Example of receive packet:
Remote mode turns to ON.
6FH, 07H, 05H, 47H, 10H, 03H, FFH
7.4 PLAY
Function: Started playback.
Data length: 2 bytes
Data: 02H, 01H
Details of function:Indicates playing status.
Example of receive packet:
Start playing.
6FH, 07H, 05H, 47H, 02H, 01H, FFH
7.5 STOP
Function: Operation has stopped.
Data length: 2 bytes
Data: 02H, 02H
Details of function: This command indicates operation has stopped by “STOP”.
When MDS enters stop mode by receiving “STOP” , it outputs this
data.
In stop mode, MDS also outputs “STATUS DATA”.
When MDS has automatically stopped after playing a disc to its end, it
does not output “STOP” but outputs “STATUS DATA”.