Tally Generation Settings 375
No.
Parameter
Adjustment
1
Destination
Address
Destination address
2
Destination
Level
Destination level
3
Tally Type
Tally type
a)
Chapter
22
Router
Interface
and
Tally
Setup
3
Set the source.
Source From: Specifies the source start address for
the wiring configuration.
Source Level: Specifies the source level for the wiring
configuration.
No.
Parameter
Adjustment
4
Source
(From)
Source start address
5
Source
(Level)
Source level
4
Press [Execute].
The settings are common to the parallel and serial tallies.
Making New Tally Generation
Settings
1
Open the Engineering Setup >Router/Tally >Tally
Enable >New menu (7364.1).
2
Set the following parameters.
Changing Wiring Settings
1
Open the Engineering Setup >Router/Tally >Wiring
>Modify menu (7363.2).
2
Referring to steps 2 and 3 in “Making New Wiring
Settings”
(
1
p. 374), change the parameters as
required. In this case, however, it is not possible to
specify multiple destinations in a single operation, and
a single address in Destination Address” must be
specified.
3
Press [Execute].
Deleting Wiring Settings
1
In the Engineering Setup >Router/Tally >Wiring
menu (7363), select the wiring.
2
Press [Delete].
Sorting Wiring Settings
In the Engineering Setup >Router/Tally >Wiring menu
(7363), press [Sort].
The sorting of wiring settings are executed in the following
order.
a) 1:R1, 2:G1, 3:R2, 4:G2, 5:R3, 6:G3, 7:R4, 8:G4, 9:R5, 10:G5, 11:R6,
12:G6, 13:R7, 14:G7, 15:R8, and 16:G8 (R is an abbreviation of
“Red Tally,” and G of “Green Tally”).
3
In the <Tally Enable> group, specify the tally
generation mode.
Enable: Always generate a tally.
Disable: Never generates a tally.
Tally Input: Generates a tally from the tally input
state.
4
If you selected [Tally Input] as the tally generation
mode in step 3, select either of the following in the
<Tally Input> group.
DCU1: Generates tally with reference to signal input
to DCU1 port.
DCU2: Generates tally with reference to signal input
to DCU2 port.
5
Select the tally input port number.
No.
Parameter
Adjustment
5
Input No
Tally input port number
6
Press [Execute].
Destination level order (ascending)
t
Destination
address order (ascending)
t
Source level order
(ascending)
Tally Generation Settings
You specify the destination to be the reference for tally
generation, and make various settings.
Modifying Tally Generation
1
Open the Engineering Setup >Router/Tally >Tally
Enable >Modify menu (7364.2).
2
With reference to steps
2
to
5
in “Making New Tally
Generation Settings
(
1
p. 375), change the
parameters as required.
3
Press [Execute].