Serial Tally Settings  377 
 
Chapter
 
22
 
Router
 
Interface
 
and
 
Tally
 
Setup
 
6 
When setting the tally type, set the following
 
parameter. 
 
 
a) 1:R1, 2:G1, 3:R2, 4:G2, 5:R3, 6:G3, 7:R4, 8:G4, 9:R5, 10:G5, 11:R6, 
12:G6, 13:R7, 14:G7, 15:R8, and 16:G8 (R is an abbreviation of
 
“Red Tally,” and G of “Green Tally”). 
7 
Press [Execute]. 
 
Deleting Parallel Tally Settings 
1 
In the Engineering Setup >Router/Tally >Parallel
 
Tally menu (7366), select the parallel tally. 
2 
Press [Clear]. 
 
 
Serial Tally Settings 
Making Serial Tally Source Address
 
Settings 
To set the serial tally source address for each port, use the
 
following procedure. 
1 
Open the Engineering Setup >Router/Tally >Serial
 
Tally >Source Assign menu (7367.1). 
2 
In the<Serial Tally Port> group, select the port to
 
which the setting applies. 
3 
Select the bit number of the port. 
4 
Select the source address. 
 
 
5 
Press [Source Address Set]. 
 
Clearing a source address setting 
 
This sets the serial tally settings, including tally type and
 
source address for each serial tally port. 
To clear a source address setting for a particular
 
bit 
In the Source Assign menu, select the serial tally port and 
 
   
 
    bit number (see steps 2 and 3 above), then press [Clear]. 
 
   
Setting or Changing Serial Tally 
Settings 
1 
In the <Serial Tally Port> group of the Engineering
 
Setup >Router/Tally >Serial Tally menu (7367), select
 
the port to which the setting applies. 
2 
In the <Tally Group> group, select the tally group. 
3 
In the <Tally Type> group, press the tally types to
 
select (you can select up to four). 
To clear all source address settings 
In the Source Assign menu, select the serial tally port, then
 
press [All Clear]. 
Check the message, then press [Yes]. 
 
To restore all source address settings to default
 
values 
In the Source Assign menu, select the serial tally port, and
 
press [Default Recall]. 
Check the message, then press [Yes]. 
 
 Notes  
The selectable tally types depend on the settings in
 
step 2. 
4 
In the <Tally Data Size> group, press one of the
 
following to select the data size. 
128 Bit: 128 bits 
256 Bit: 256 bits